Flame-out protection device working principle as follow:
Flame- out protection working principle Flame-out protection device working principle, for gas product: press
down the knob to have gas access and then ignite the burner. Thermocouple got heated up by the flame,
and it creates thermoelectric potential, thermoelectric potential induce into electromagnetic coil through
the wire, it creates magnetic field which makes electromagnetic valve operate, gas valve is enabled, firing
aisle is open. Remain normal combustion, when it encounters strong wind or soup overflow, and the flame
went off , thermoelectric potential will go down to zero in a very short time, electromagnetic coil loss power,
so electromagnetic valve stop working , it will be reset under the action of the spring, valve will cut off the gas
access , cut off gas supply, ensure safety .
Troubleshooting:
PROBLEM
Gas Smell
Strong Smells
Noise
Electric components to
not function
When turning on the
lamp,the roasting rod
POSSIBLE CAUSE
Connection hose or tubing puncture
Burners incorrect position
An oven burner in use accidentallywent
off
Pressure regulator badly installed
Oil and grease used to manufacture you
stove
Metal expansion due to heat
Disconnected stove socket without power
36
GAS COOKER
TCG020520MD
SOLUTION
Change the installation
Place them in the correct
position.
Call the costumer service
Install it correctly
It is normal the first time you use
it.
Normal
Connect the electric cord Check
the socket connecting a lamp.
It is normal.