Electrical installation
5.2.
Make sure you have read and checked all the precautionary notes in chapter 5.1.
• Prepare the DW wand by installing the most suitable accessory for the type of work to be carried out (see chapter 4).
• Connect the ground cable connector (A) to the red socket on the front panel of the unit.
• Use the crocodile terminal of the ground cable (B) to grip the piece of stainless steel to be treated.
• Use the supplied cable to carry out the electrical installation of the DW wand; connect the female connector (C) to the DW
wand (D) and insert the male connector into one of the designated black sockets on the front panel of the unit (E).
• The SURFOX MAX can operate with two wands at the same time. When using a single wand, choose one or the other
socket indifferently.
• Connect the device power cord to a suitable socket.
22
B
A
E
C
D