Energy SLT966 Instrucciones De Uso Y De Montaje página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
SLT966 SLT967
FREE STANDING – FILTERING
VERSION INSTALLATION
Take the product out of the packaging and
place it on a suitable surface: we suggest to
use a soft material, such as a sponge or a
cloth.
Open the glass panel , rotating it as shown in
Fig. 1, and remove the grease filters.
BEFORE INSTALLATION , IN ORDER TO AVOID
ANY POSSIBLE DAMAGE TO THE GLASSES,
WE RECOMMEND TO REMOVE THEM BY UN-
SCREWING THE EIGHT SCREWS SHOWN IN FIG.
10. ELECTRICALLY DISCONNECT THE LED
BARS, BY USING THE SPECIFIC BIPOLAR AC-
TUATOR, AND REFIT THE GLASSES AND THE
ELECTRIC WIRING ONCE INSTALLATION IS
COMPLETED.
Drill the holes on the ceiling , as shown in Fig.
2, insert the plastic plugs into the holes made,
and then fix the ceiling brackets, as shown in
Fig. 3. The brackets, which being telescopic
can be adjusted in height , shall be secured at
their minimum extension.
Bring the hood close to the brackets previou-
sly fixed and connect the appliance to the
supply mains.
Secure the hood to the ceiling, by using the
screws supplied, as shown in Fig. 4.
SLT966 SLT967
BUILT IN – SUCKING VERSION
Take the product out of the packaging and pla-
ce it on a suitable surface: we suggest to use a
soft material, such as a sponge or a cloth.
Open the glass panel , rotating it as shown in
Fig. 1, and remove the grease filters.
BEFORE INSTALLATION , IN ORDER TO AVOID
ANY POSSIBLE DAMAGE TO THE GLASSES,
WE RECOMMEND TO REMOVE THEM BY UN-
SCREWING THE EIGHT SCREWS SHOWN IN FIG.
10. ELECTRICALLY DISCONNECT THE LED BARS,
BY USING THE SPECIFIC BIPOLAR ACTUATOR ,
AND REFIT THE GLASSES AND THE ELECTRIC WI-
RING ONCE INSTALLATION IS COMPLETED.
In the built-in installation, the stainless steel
external cover is not necessary (Fig. 5).
A recess shall be created , where the appliance
will be placed, which shall have a 730 mm X
450 mm rectangular opening and depth ran-
ging from 110mm to 190 mm.
INSTALL THE HOOD ON THE CEILING, CON-
NECT THE CANAL SYSTEM FOR THE AIR
OUTLET, SET THE ELECTRICAL CONNEC-
TION AND THEN COMPLETE THE PLASTER-
BOARD STRUCTURE.
The recess shall be provided with a socket and
a round pipe of 150mm diameter, or a similar
section, for the air outlet.
Drill the holes on the ceiling , as shown in Fig. 2,
insert the plastic plugs into the holes made, and
then fix the ceiling brackets as shown in Fig. 3.
The ceiling brackets are telescopic , so their
height can be adjusted at 80 mm between the
ceiling and the hood.
You can choose one of the three air out- lets
shown in Fig. 6: fit the air outlet plastic flan-
ge in the desired outlet; the remaining outlets
shall be closed with the specific metal caps , as
shown in fig. 6.
Bring the hood close to the brackets previou-
sly fixed and then connect the appliance to the
supply mains.
Secure the hood to the ceiling, by using the
screws supplied, as shown in Fig. 4.
13
BUILT IN
Tabla de contenido
loading

Productos relacionados para Energy SLT966

Este manual también es adecuado para:

Slt967

Tabla de contenido