USE ELCOMETER ANTISTATIC AIR HOSES. SHOULD AN ANTISTATIC AIR
HOSE NOT BE AVAILABLE, YOU MUST ATTACH THE UNIT TO A GROUND
CONNECTION IN ORDER TO ELIMINATE ANY STATIC ELECTRICIT
You must always connect the equipment and all the elements involved in the work process
to a grounding connection to eliminate static electricity. Regularly verify (one a week) its
electrical continuity. If its resistance exceeds the recommended limits, it must be fixed. An
equipment unit without or with a faulty grounding connection may make the installation
dangerous.
The total derivative resistance must be <1 million Ohms (Ω).
Read and carefully apply all the information, instructions and safety measures given by the
manufacturer of the products to be used (products to be applied, solvents, etc.), as chemical
reactions, fire and/or explosions may occur. These may be toxic, irritant or noxious and in any event
are dangerous for the health and wellbeing of the user and the personnel around him (See section
on Health and Safety).
Mix, prepare and filter the product to be applied in accordance with the
manufacturer's instructions, ensuring that no foreign particles ruin the
quality of the finish and application. Should there be any doubt on the purity
of the product, its composition, etc., please contact your supplier.
Control the viscosity of the product to be applied by means of ELCOMETER
2435 Viscosity Kit.
Ensure that the lid and tank close perfectly, keeping
the parts that come into contact (tank and lid) free of
product.
Avoid moving the pressure pot or laying it on its side with
product inside
Leave minimum of 10 cm. Free between the product and
the lid.
¡BE CAREFUL ABOUT EXPLOSION!
Be sure to use pressure tank at less than max. fluid working pressure.
Use at more than max. fluid operating pressure can cause explosion of
pressure tank resulting in great danger. Securely connect hose to avoid
leak and looseness. If hose is disconnected during operation, hazardous
hose movement and paint ejection will cause severe bodily injury.
If the equipment is going to remain for a long time running empty, disconnect it from the general air
network.
www.elcometer.com
min.
10 cm.
EN