Rangemaster RMDD3004 Manual Del Usuario página 5

Ocultar thumbs Ver también para RMDD3004:
Idiomas disponibles

Idiomas disponibles

®
Downdraft
PLAN THE WIRING
I
1. The Interior Downdraft
Blower system draws 4 AMPS and
requires a 120 VAC, 60 Hz circuit.
2. The unit has a 18 in. tong power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit's power cord to reach.
IMPORTANT - LOCATION OF ELECTRICAL OUTLET:
If Model RMDD3004
is being installed in a 30" wide
cabinet...
or Model RMDD3604 is being installed in a 36" wide
cabinet...
or Model RMDD4804 is being installed in a 48" wide
cabinet...
...the outlet cannot be located on the back wall
of cabinet.
In these cases, the width of the downdraft covers nearly the
entire width of the back walt of the cabinet. So you must
either:
mount the electrical box to a side wall or cabinet floor
- at least 12 inches from the back wall.
mount the electrical box to a wall stud behind the
cabinet - where it will not be covered by the downdraft.
Then provide a clearance hole in the back wall of the
cabinet.
Ventilators
Page 5
1. The Exterior Downdraft
Blower system draws 6 AMPS and
requires a 120 VAC, 60 Hz circuit.
2. The unit has a 18 in. tong power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit's power cord to reach.
IMPORTANT - LOCATION OF ELECTRICAL OUTLET:
If Model RMDD3004EX
is being installed in a 30" wide
cabinet...
or Model RMDD3604EX
is being installed in a 36"
wide cabinet...
or Model RMDD4804EX
is being installed in a 48"
wide cabinet...
...the outlet cannot be located on the back wall
of cabinet.
In these cases, the width of the downdraft covers nearly the
entire width of the back walt of the cabinet. So you must
either:
mount the electrical box to a side wall or cabinet floor
- at least 12 inches from the back wall.
mount the electrical box to a wall stud behind the
cabinet - where it will not be covered by the downdraft.
Then provide a clearance hole in the back wall of the
cabinet.
PREPARE
THE DOWNDRAFT
The downdraft is shipped with duct connector pointing toward the
bottom of the unit. If you wish to change this orientation, follow the
steps below:
1. Place the downdraft on its back on a table of fiat work surface.
2. Remove the 4 nuts and 2 clamp channels.
3. Remove 2 screws and the gear motor cover.
4. Carefully position the blower under the bottom flange of the
downdraft with the 3¼" x 10" discharge
(3¼" x 14" for
exterior
blower)
pointed in the desired direction.
5. Connect motor
plug.
6. Replace the gear motor cover and 2 sheet metal screws.
7. Replace the 2 clamp channels and start the 4 nuts, do not
_hten.
8. Slide blower left of right to desired position. Use cover plate
(supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use additional
screws
(supplied) through bottom flange to secure bottom in blower.
NUTS
CHANNELS
I_
SCREWS
_
I-
GEARMOTOR
COVER
I
ii
3¼"XI0"DISCHARGE
(3¼" X 14" FOR EXTERIOR BLOWER)
/
\
\
COVER
MOTOR
PLATE
PLUG
_
ADDITIONAL
SCREWS
BOTTOM
FLANGE
loading

Este manual también es adecuado para:

Rmdd3604Rmdd4804Rmdd3004exRmdd3604exRmdd4804ex