After opening the regulator, check that
there are no gas leaks by applying soapy
water with a paintbrush to the union of
the flexible tube with the space heater
and the regulator.
Fit the back panel using the attached
fixing lugs (fig. 3).
CAUTION: For their own safety, keep the
package (cardboard, Styrofoam, plastic
bags, etc.) away from your children.
Note: The replacement of the cylinder
should be carried out in a non-flammable
environment.
The space heater includes a safety
device, which turns the device off and
extinguishes the pilot flame if the
ventilation in the premises is insufficient
or the concentration of CO2 exceeds the
maximum stipulated by law.
It is usual for this device to operate in
very small premises.
If the flame does go out, ventilate the
room well and wait a few minutes before
reigniting the space heater.
Ignition instructions
Attention: before using the space heater
for the first time and after long periods
of non-use, we recommend switching on
the control buttons several times
alternately and without gas flow in order
to facilitate its operation.
The space heater can be regulated to three
different heat intensities: MAXIMUM,
MEDIUM and MINIMUM. The ignition
mechanism is piezo-operated.
Open the gas outlet by rotating the lever
on the regulator to the correct position
(Fig.2).
Turning on the space heater
Press the button and rotate it to your left,
holding it down for 20 seconds. Repeat this
procedure several times if necessary until the
pilot light ignites near the bottom part of the
protective screen guard (where the spark is
seen), Fig.4 and keep pressing the button for
10 seconds. If, on releasing the button, the
flame goes out, please repeat the whole
procedure.
For MINIMUM heat - Rotate the button to
For MEDIUM heat - Rotate the button to
For MAXIMUM heat - Rotate the button to
Maintenance
If any anomaly is observed or spare parts
are required, contact our Technical
Service.
The periodical maintenance must be
carried out exclusively by an authorized
technician.
We would recommend that you have a
service carried out annually by an
authorized technician.
Watch the pilot light, which should be
stable.
Check to see if it is necessary to change
the flexible gas tube. If it proves
necessary, obtain a new tube and
connect it as explained in "Heater
start-up".
It is recommended that the cleaning of
the device be carried out with the gas
regulator closed, the heater completely
cold and with nonabrasive products.
The heater must be cleaned wearing
gloves.
When the space heater is not in use, we
recommend storing it in a dust-free
atmosphere, protected with a cloth or
plastic cover in a dry place.
Warranty
All our space heaters have been
meticulously checked before leaving the
factory. Nevertheless, if any anomaly is
observed remember that our extensive
Technical Service network is at your
disposal. You should read the section,
"Before calling in Technical Service" to
verify if you can remedy the anomaly
yourself.
Before calling in Technical Service
The space heater doesn't turn on
Check to see if there is gas in the cylinder
and that the regulator is correctly coupled
in the open position.
Check to see if the flexible tube is
properly connected.
Check that the instructions have been
followed correctly.
If this occurs after changing cylinders it
may be due to:
There is air in the cylinder. Press the
ignition button down for a longer period
of time until the pilot flame and burner
ignite. Then switch to the MAXIMUM
position.
The bottle may have been exposed to
low outside temperatures. Apply fairly
hot wet cloths to the upper part of the
bottle to increase gasification and the
normal output of gas.
The space heater goes out
If it goes out on completing the ignition
instruction, repeat the operation, following
the instructions carefully.
If it goes out after 30 minutes, it means
that it is operating in a poorly ventilated
atmosphere. Ventilate the room and
reignite the space heater.
If it goes out before 30 minutes of
operation, ensure that it is not exposed
to air drafts or that the cylinder has not
run out of gas.