EXTERIOR
OR IN-LINE
BLOWER
SELECTION
CAUTION: Either an exterior blower or in-line blower may be used with this hood.
The RM61000EX hood must be installed with blower models 331 H, 332H, 335,336,
HLB3, HLB6, HLB9 or HLB11 only. Other Blowers cannot be substituted (Blowers
sold separately).
The blower must be UL listed for Canadian and U.S. use, and evaluated for use with
solid state speed control, rated 120V, 60 Hz, 6.0 A max.
INSTALL
THE DUCTWORK
NOTE: To reduce the risk of fire, use only metal ductwork.
1. Choose the location where the Exterior or In-Line Blower will be mounted. See
illustrations below for mounting location suggestions
and restrictions.
2. A straight, short duct run will allow the hood to perform most efficiently.
3. Long duct runs, elbows and transitions
will reduce the performance
of the
hood. Use as few of them as possible. Larger ducting may be required for best
performance with long duct runs.
4. After the Exterior or In-Line Blower has been installed, connect round metal
ductwork and work back towards the hood location. Use duct tape to seal joints
between ductwork sections.
5. An 8" round to 10" round transition
(Model
414) is required.
For best air
performance,
install the transition as close to the range hood as possible.
CAUTION:
MAY NOT
FIT
UNDER EAVES
OF SINGLE
STORY
HOMES
SUGGESTED
MOUNTING
LOCATIONS
OK
OK
EXTERIOR
BLOWER
I0" ROUND
EXTERIOR
DUCT
8"ROUND
DUCT
DECORATIVE
FLUE
HOOD
\
24"TO30"ABOVE
COOKING
SURFACE
8"TOt0"
ROUND
ADAPTER
ROUND
DUCT
8"ROUND
ELBOW
-5-