World Marketing of America Comfort Gear PPH10 Manual De Instrucciones página 7

Idiomas disponibles

Idiomas disponibles

LIGHTING, OPERATION, AND
SHUTDOWN INSTRUCTIONS
Unvented Portable Type Heaters Must Not be Exposed to Flammable
Vapors or Liquids.
1. Make sure the control knob is in the OFF position.
2. Open the access door as needed and install the one pound cylinder(s)
as described on page 5.
Check for gas leaks by using a 50% soap-water solution at
the joint of the regulator and cylinder.
3. Depress and turn the control knob to the pilot position.
a. If fueled by a 1 lb. propane cylinder, hold for 30 seconds.
b. If fueled by a 20 lb. propane cylinder, hold for 4-5 minutes.
With the knob still depressed, rotate the knob between the OFF and
PILOT position activating the piezo igniter until the pilot fl ame ignites.
4. Continue holding the knob down in the PILOT position
for 30 seconds or until pilot fl ame holds.
5. Release the knob. The knob should return to the fully
extended position and the pilot should remain lit.
6. Turn on the burner by depressing the knob slightly and
gently turning the knob to the HI position.
7. Adjust heat output by turning the knob between HI and
LOW position.
8. To shut down the heater ,turn the knob clockwise to the OFF
position and remove the gas cylinder or close the propane
tank shut off valve and allow the heater to burn off the gas in
the hose, then turn the heater knob to the OFF position.
CAUTION
Do not try to adjust heating levels by using the propane tank shutoff
valve. After turning heater off, the guard will remain hot. Allow the
heater to cool down before storing the heater.
Do not operate, store, connect or remove cylinder/hose connection near
fl ammable items or ignition sources.
LIGHTING / OPERATING INSTRUCTIONS
FOR USE WITH HOSE(S) CONNECTED TO A
REMOTE CYLINDER, MAXIMUM SIZE 20 LBS:
• This Heater may be used in a Recreational Enclosure or
Temporary Construction Work Enclosure with a Remote
Refillable Propane Cylinder ONLY when the Cylinder is
Located Outdoors and the Heater is Used with WMAI
Hose No. 20-7512F.
• WMAI Hose No. 20-7512F includes a hand-tightening tank
connector, a fuel filter and a #600 hose connector fiitting
WARNING: NEVER bring a refillable propane cylinder indoors.
A fire or explosion can occur causing property damage, serious
injury or death!
• Inspect the hose before each use of the heater. If there is
excessive abrasion or wear or the hose is cut, replace prior to
using the heater with WMAI 20-7512F.
• The propane cylinder must include a listed overfi lling protection
device as well as a collar to protect the cylinder valve.
• Heater must be in an upright position during operation.
• Connect propane as described on page 6.
• Open valve at LP-gas supply cylinder.
• Check all hose connections for leaks with soapy water at all threaded
connection points and at the LP-gas supply cylinder.
SEE WARNING! ON ATTACHED LABELS.
• Follow the instructions for lighting the Heater as defi ned in steps 1
through 8 above.
LIGHTING IN WINDY AREAS
1. Position the heater such that the Pilot is opposite the direction that
the wind is coming from. See fi gure 3
2. Position your body behind the heater such that your body blocks the
wind while you are following the instructions for lighting the unit.
PILOT
Fig. 2a - Model 10K Lighting Control Panel
PILOT
Fig. 2b - Model 18K Lighting Control Panel
WIND
DIRECTION
Fig. 3 - Lighting in Windy Areas
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
7
OFF
LOW
HIGH
OFF
HIGH
MEDIUM
LOW
PILOT
POSITION
loading

Productos relacionados para World Marketing of America Comfort Gear PPH10

Este manual también es adecuado para:

Comfort gear pph18