HotShot HYPH6001-3 Manual Del Usuario página 15

Idiomas disponibles

Idiomas disponibles

Problem
The burner will not light�
The burner flame goes off
immediately after ignition�
The ignition is delayed�
The combustion on the burner is
inadequate�
The burner flame is low�
The emitter glows uneven�
There is slight smoke and odor
during initial operation�
There is thick black smoke�
The heater produces a whistling
noise when the burner is lit�
The heater produces a clicking
noise just after the burner is lit
or turned off�
There is a gas odor even when
the control knob is in the OFF
position�
There is a gas odor during
combustion�
There is carbon build-up�
Cause
The burner injector is clogged�
There is low gas supply pressure�
There is low gas pressure�
The main burner carryover ports are clogged�
There is low gas pressure�
There is not enough air�
The supply hose is bent or twisted�
There is blockage in the burner injector�
There is blockage in the burner
injector�
The base is not on a level surface�
The gas pressure is low�
This is residue from the
manufacturing process�
There is blockage in the burner�
Air passageways are blocked�
There is air in the gas line�
The metal is expanding and
contracting�
There is a gas leak�
The gas control is defective�
There is foreign matter in the gas or
on the burner ports�
The heater is burning vapors from
paint or impurities in the air�
There is gas leaking from the
regulator and hose connection, the
valve and pipe connections, and the
pipes�
There is dirt or film on the reflector
and flame screen�
TROUBLESHOOTING
Solution
Clean the burner injector�
Call your gas supplier�
Call your gas supplier�
Clean the main burner ports�
Call your gas supplier�
Check the air passageways and burners for
dirt and debris, and clean with compressed air�
Straighten the hose and perform a leak test�
Clean or replace the burner injector�
Clean or replace the burner injector�
Place the heater on a level surface�
Replace the cylinder with a new cylinder�
This will stop after approximately 30 minutes
of operation�
Turn off the heater and let it cool�
Remove the blockage and clean the
inside and outside of the burner�
Check the minimum installation
clearances and air passageways for
debris�
Operate the burner until the air is
completely purged�
This is common with heaters� If noise is
excessive, contact a qualified service
person�
Locate and correct the leak
immediately�
Replace the gas control�
Check the gas passageway and burner�
Stop storing and using odor causing
products near the heater�
Locate and correct the leaks, or contact
your gas supplier�
Clean the reflector and flame screen�