SN2008 - TouchTime
®
3
Electrical and Supply Connections
WARNING The TouchTime activation must be connected with a 12V DC plug in adapter. Connections to
110 VAC can cause personal injury and will result in damage to the electronics.
Mechanical pushbutton shown, piezo switch similar.
Activation of the push button takes place only when it
is released, thereby preventing "hold open" activation.
STOP!!! If installing optional Shroud/Slip Ring or Towel
Dispensers, complete those installations before proceeding
to Step 5 (see Optional Equipment Installation page).
Mechanical Pushbutton
shown (S83-368)
Piezo Switch Similar
(S83-369)
E
Connect plug-in
adapter to splitter .
Splitter
(251-027A)
4
Adjusting the TouchTime Module
The TouchTime module is set at the factory with the selector
switch in position 5. This provides a 11 second time out period.
The 24 hour flush function will activate water flow for a period
of 60 seconds any time there has been no activation within the
past 24 hours. This function is used to help clear stagnant water
from the plumbing system and can provide some measure of
prevention against the formation of bacteria in supply pipes.
To adjust the TouchTime module to a different
A
time out period, turn the selector switch to
the desired time out setting (4 through 9 for
no flush, A though F for 24 hours flush) as
indicated on the module label .
6
TouchTime
Module (8x)
Splitter
(251-027B)
Plug-In Adapter
(261-147A)
Pushbutton
Connectors (Can use
either one or both)
7/10/2019
Loosen the compression nuts .
A
Push the sprayhead supply tubes firmly into the
tube connectors until they are fully seated .
Tighten the compression nuts by hand .
Supply Tube From Sprayhead (Colors from left to right:
yellow, black, green red, yellow, black, green, red)
B
Connect button
C
connector to TouchTime
module (8x) .
Connect valve
D
connector to TouchTime
module (8x) .
LED Indicator
Selector Switch
Power
Connection
Bradley • 215-1761 Rev. C; ECO 19-00-022
Installation
Compression
Nut (8x)
Connect splitter
connector to TouchTime
module (8x) .