UK
Troubleshooting
If your appliance develops a fault, please check the following table before making a call to the Helpline.
Fault
The appliance is not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The appliance turns
Condenser blocked with dust
on, but the
Doors are not shut properly
temperature is too
Appliance is located near a heat
high/low
source or air flow to the
condenser is being interrupted
Ambient temperature is too
high
Insufficient airflow to the fans
Appliance is overloaded
Factory default parameters
adjusted
The appliance is
The appliance is touching a
unusually loud
neighbouring object
The appliance has not been
installed in a level or stable
position
Technical Specifications
Model
Voltage
BBC138 230V 50Hz
BBC208H 230V 50Hz
BBC208S 230V 50Hz
BBC330H 230V 50Hz
BBC330S 230V 50Hz
BBA138 230V 50Hz
BBA208 230V 50Hz
BBA330 230V 50Hz
5
Probable Cause
Temperature
Power
Current
Range
180W
1.3A
2°C to 8°C
230W
1.8A
2°C to 8°C
230W
1.8A
2°C to 8°C
350W
2.4A
2°C to 8°C
350W
2.4A
2°C to 8°C
180W
1.3A
2°C to 8°C
230W
1.8A
2°C to 8°C
350W
2.4A
2°C to 8°C
Check the unit is plugged in correctly and switched on
Call agent or qualified Technician
Replace the fuse
Check power supply
Call agent or qualified Technician
Clean Condenser
Check doors are shut and seals are not damaged
Move the appliance to a more suitable location
Increase ventilation or move appliance to a cooler position
Remove any blockages to the fans
Reduce the amount stored in the appliance
Call agent or qualified Technician
Check installation position and change if necessary
Check installation position and change if necessary
Capacity
Refrigerant
(litres)
138
R600a
208
R600a
208
R600a
330
R600a
330
R134a
138
R600a
208
R600a
330
R600a
Action
Dimensions
H x W x D (mm)
900 x 600 x 520
900 x 900 x 520
900 x 900 x 520
900 x 1350 x 520
900 x 1350 x 520
900 x 600 x 520
900 x 900 x 520
900 x 1350 x 520
Weight
(kg)
48
62
62
80
80
48
62
80