Ravaglioli J40PMB Manual De Instrucciones página 43

PROBLEMS
The pump does not
start or stops during the
operation (before
reaching the maximum
pressure).
The pump works but
does not send oil.
Low capacity.
The pump does not
reach the maximum
pressure.
The pump reaches the
maximum pressure but
does remain under
pressure.
Excessive oil leaks
from the air drainage.
Oil tank gets up to
pressure with air and oil
leaks from the valve.
The pump continues
pumping even after
releasing the button.
After a period of disuse,
the pump does not
start.
CAUSES
a)
Return spring broken.
b)
Air loss, check the piston seal.
a)
Oil level low.
b)
Pump does not prime.
a)
Tank not ventilated.
b)
Insufficient air capacity.
c)
Hydraulic causes:
-
Check that the oil filter is not blocked.
-
Air in the hydraulic circuit.
- Check that the ball of the suction valve
works properly.
a)
Check the air pressure.
b)
Valve or gaskets faulty or dirty.
a)
Check hydraulic connections.
b)
Dirt under the pedal.
c)
The ball of the delivery valve.
d)
Leakage on the apparatus connected.
a) Gaskets faulty.
a)
Air leakage from the gaskets.
b)
Tank too full of oil.
a)
Gaskets faulty.
b)
Air valve spring broken or too weak.
a) Gaskets faulty.
REMEDIES
a)
Replace.
b)
Replace if faulty.
a)
Top up oil.
b)
Press the button
at the same time as the air valve to start
the motor.
- Bleed the air out.
- Pressurize the tank.
CAUTION Max. pressure 0.5 Bar
(7 P.S.I.).
- Remove and clean.
a)
Ventilate tank through the screw on
the plug.
Capacity should be 250 Lt/minute.
b)
c)
- Clean or replace.
- Bleed air from the circuit.
- If necessary add a copper washer or
replace coupling if the housing is worn.
a)
7 bar (100 P.S.I.) is required.
b)
Clean or replace.
a)
Tighten if necessary.
b)
Clean.
c)
Replace gaskets.
d)
Repair and check seal.
a) Replace.
a)
Replace gaskets.
b)
Check the level.
a)
Replace.
b)
Replace.
a) Replace.
loading

Este manual también es adecuado para: