Expert debugging functions
Setting
Functions
code
Restore
factory
8888
settings
Water
shortage
F1
protection
switch
Hibernation
delaytime
F2
setting
Screen
backlight time
F3
setting
Maximum
F4
speed setting
Leakage
indicator
F5
setting
Anti-block
F6
setting
Anti-block
F7
setting
Function description
ln the standby mode, press
"Setting" key and "-" key
simultaneously, all symbols light
up, the LED displays 8888, the
display value is back to normal 3
seconds later, and the parameter
settings are restored to factory
settings.
ln F1 setting mode, click"+/- key"
to enable or disable the water
shortage protection.
ln F2 setting mode, click "+/- key"
to set the hibernation delay time.
ln F3 setting mode, press "+/- key"
to set the screen backlight time.
ln F4 setting mode , press "+/-
key" to set the maximum speed.
ln F5 setting mode, press "+/- key"
to set the start pressure drop
value. The setting range is 2-10m.
ln F6 setting mode, press "+/- key"
to set the leakage indicator.
ln F7 setting mode, press "+/- key"
to enable or disable the anti-block
function.
Remarks
If not in the standby mode, press the "On/Off'
key to stop the water pump first.
F1.1: indicates the water shortage protection is
enabled .
F1.0: indicates the water shortage protection is
disabled .
Water shortage protection is enabled by default.
lt can be set between F2.5- F2.60 which is
between 5 seconds-60 seconds.
Press "+/- key" one time to set the time by 1
second. The factory default inactivity delay time
setting is 5 seconds.
F3.00: the screen backlight is continuously
illuminated.
F3.30: the screen backlight is illuminated for 30
seconds .
F3.60: the screen backlight is illuminaled for 60
seconds.
F3.90: the screen backlight is illuminated for 90
seconds.
Four settings are optional for the screen backlight
illuminated time: 30 seconds, 60 seconds, 90
seconds, and continuously illuminated, and the
default setting is 30 seconds.
F4.0: max. speed 3000 rpm.
F4.1: max. speed 4200 rpm.
F4.2: max. speed 5200 rpm.
Three levels of maximum speed are optional,
and the default setting is 5200 rpm.
It can be set between F5.2 and F5.10 which
means it is allowed to set the start pressure =
Set pressure start pressure drop value.
The default setting is 5m.
F6.0: leakage indicator is disabled.
F6.1: leakage indicator is enabled.
The leakage indicator is enabled by default.
F7.0: anti-block indicator is disabled.
F7.1: anti-block indicator is enabled.
The anti-block indicator is enabled by default.