NEXA MODULAR GB2 VIDEO DOOR ENTRY SYSTEM - BUILDING
SAFETY PRECAUTIONS
-
Always disconnect the power supply before installing or making modifications to the devices.
-
The fitting and handling of these devices must be carried out by authorised personnel.
-
The wiring must run at least 40 cm away from any other wiring.
-
On the power supply unit (FA-GB2/A):
Do not overtighten the screws on the connector.
w
Install the power supply unit in a dry and protected place free from the risk of water leaks or sprays.
w
wAvoid locations that are humid, dusty or near heat sources.
wEnsure that the air vents are free from obstruction so that air can circulate freely.
wTo avoid damage, the power supply unit must be firmly secured in place.
wTo prevent electric shock, do not remove the cover or handle the wiring connected to the terminals.
( )
CHARACTERISTICS
*
-
Video door entry system with simplified wiring (non-polarised 2-wire bus).
-
Up to 4 access panels (DP-GB2A distributor required for more than one access panel) per
installation.
-
Up to 23 monitors and apartments with a Vesta2 monitor per installation.
-
Up to 18 monitors and apartments with a Vesta7 monitor per installation.
-
Up to 128 telephones and apartments with T562/TNHEA telephones per installation.
(It is necessary to set the EL632 GB2A module to operating mode 2 'audio only').
-
Up to 4 monitors per apartment.
-
Call confirmation tone.
-
Visual signals on the door panel for people with impaired hearing (indicating call process,
communication, door open and channel busy).
-
Audible signals on the door panel for people with impaired vision (indicating call in progress,
missed call, door open, call finished and engaged).
-
Operating modes can be set on the EL632/GB2A sound module.
SYSTEM OPERATION
-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that
the call is being made and LED
will turn on. If vocal synthesis is enabled, a 'Call is in progress'
message appears indicating that a call is being made. At this moment, the apartment's monitors
receive the call. If another apartment is called by mistake, press the button for the correct
apartment and the first call will be cancelled.
-
In systems with several access doors, the other door panel(s) will be automatically disconnected.
If another visitor tries to call, a number of telephone tones will be heard to indicate that the system
is busy and LED
will illuminate. If vocal synthesis is activated, the message "System is busy,
try later" will be indicated on the door panel.
-
The call lasts for 40 seconds and, when received, the image appears on the master monitor
without the visitor knowing. To view the image on a slave monitor, this function needs to have
been activated on the monitor. If the call is not answered within 40 seconds, LED
and the channel will be freed.
-
To establish communication, press button
LED
will turn on.
-
Communication will last for 90 seconds or until push button
communication has finished, LEDs
and
synthesis is activated, a 'Communication is finished' message will indicate that the call is over.
If the door panel has an EL3002 GB2/H module with icon
the EL3002 GB2/H module will illuminate. Make sure that the hearing aid is 15-25 cm away from
the door panel to ensure maximum audio quality during communication with the apartment.
-
To open the door, press button
during the call or communication processes: one press will
activate the lock release for five seconds and LED
synthesis is enabled, a 'Door Opened!' message will be indicated on the door panel.
-
For a description of the functioning and setup of the monitor, see the monitor's user manual.
( )
For more information, see the T632/GB2A user manual (code 50121981).
*
https://doc.golmar.es/search/manual/50121981
All manuals and user guides at all-guides.com
will turn off
on any monitor in the apartment. Door panel
is pressed again. When
will turn off and the channel will be freed. If vocal
displayed on the front, the LED of
will also turn on for five seconds. If vocal
2
NEXA MODULAR GB2 VIDEO DOOR ENTRY SYSTEM - BUILDING
INSTALLATION OF THE DOOR PANEL
( )
*
1850
1650
1450
EL632/GB2A
VESTA2
C d Monitor
o e
ON
DIP
C. 01
1 2 3
4 5
6
ON
DIP
C. 10
1
2
3
4
5
6
ON
DIP
C. 08
1
2
3
4
5
6
ON
DIP
C. 06
1 2 3
4 5
6
ON
DIP
C. 04
1 2 3
4 5
6
ON
DIP
C. 02
1 2 3
4 5
6
( )
*
Description and settings:
-
EL632/GB2A sound module operating mode settings.
-
Description of the visual signals on the door panel.
-
Description of the door panel lighting LEDs (for low light conditions).
-
Description of the vocal synthesis (audible signals on the door panel).
-
Adjusting the vocal synthesis
( )
*
Adjusting the door panel communication volume.
To adjust the audio volume on the door panel, perform the following steps:
-
Call an apartment.
-When the call is received in the apartment, establish communication by pressing button
the monitor.
-
Then press the button used to call the apartment for 3 seconds until a number of confirmation
tones are heard and the door panel communication LED
-
Each press on the call button will increase the door panel volume and blink speed of LED .
There are 5 volume settings and the blink speed of LED
blink - low to high volume. After reaching setting 5, maximum blink speed and volume, the next
setting is 1, minimum blink speed and volume (carousel mode).
-
To save the volume setting keep the button pressed until a number of confirmation tones are
heard and the door panel communication LED
( )
For more information, see the T632/GB2A user manual (code 50121981).
*
https://doc.golmar.es/search/manual/50121981
Embedding box dimensions:
M dul s
o
e
1
2
Model
N
CE 90C
V
S
N
CEV90C
W
(width)
99
99
H
(height)
135,5
238
328 mm.
D (depth)
40
56
C d Monitor
o e
ON
DIP
C. 30
1 2 3
4 5
6
ON
DIP
C. 28
1 2 3
4 5
6
VESTA2
ON
DIP
C. 26
1 2 3
4 5
6
ON
DIP
C. 24
C d Monitor
o e
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 22
C. 00
1 2 3
4 5
6
1 2 3
4 5
6
EL610D
ON
DIP
ON
DIP
C. 09
C. 20
1 2 3
4 5
6
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 07
C. 18
1 2 3
4 5
6
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 05
C. 16
1 2 3
4 5
6
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 03
C. 14
1 2 3
4 5
6
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 11
C. 12
1 2 3
4 5
6
1 2 3
4 5
6
language/
volume
and contact type for relay1/relay2.
starts to blink.
will increase for each. Slow to fast
turns off.
3
3
CEV90
99 mm.
56 mm.
EL610D
C d Monitor
o e
ON
DIP
C. 29
1 2 3
4 5
6
ON
DIP
C. 27
1 2 3
4 5
6
ON
DIP
C. 25
1 2 3
4 5
6
ON
DIP
C. 23
1 2 3
4 5
6
ON
DIP
C. 31
1 2 3
4 5
6
EL610D
ON
DIP
C. 19
1 2 3
4 5
6
ON
DIP
C. 17
1 2 3
4 5
6
ON
DIP
C. 15
1 2 3
4 5
6
ON
DIP
C. 13
1 2 3
4 5
6
ON
DIP
C. 21
1 2 3
4 5
6
on