Operation
• Turn on the compressor and fill it.
• Regulate the air compressor output pressure to 75 PSI and
110 PSI
WARNING
The tool operates with this pressure
range. If operating with a higher pressure ranges the useful
life of the tool will be decreased.
• Load the cartridge as indicated on page 7.
CAUTION
• Use a piece of scrap wood to verify the
tool works correctly.
• Not putting your finger on the trigger position the tool and
press the contact lock against the surface to be used (A).
• Without lifting the tool press the trigger to shoot (B).
• Immediately release the trigger and lift the tool (C).
• Position the tool back for subsequent shots.
• In case the nails are not penetrating deep enough, slightly
lift the air pressure until reaching the right penetration force.
WARNING
Remember not to exceed 110 PSI
A
Blocked staple in the shooting orifice
• Disconnect the tool from the air supply.
• Open the nozzle (D) and pull the nail using pliers until
removed (E).
Blocked staple in the cartridge
• Disconnect the tool from the air supply.
• Open the cartridge (F).
• Remove the blocked nail with pliers.
• Close the cartridge.
8
ENGLISH
B
E
D
Start Up
C
F