CONFIGURATION WITH THE VMF SYSTEM
VMF-E4 VMF SERIES THERMOSTAT CONTROL PANEL, WALL MOUNTING
VMF-E4
VMF-E4
FCLI + GLLI10N
FCLI + GLLI20N
Example of a TTL local network consisting only of FCLIs
LUNGHEZZA MAX.30 (m)
FCLI
FCLI
SLAVE
SLAVE
Example of a TTL local network consisting of mixed
fan coils
MAX 30m
FCLI + GLLI10N
FCLI + GLLI20N
FCX + VMF-E1
FCL + GLL10N
FCXI + VMF-E18
FCL + GLL20N
28
Wired control panel, user interface for thermostats incorporated
The panel must be used with VMF range thermostats and operates
Wall mounting with connection cable.
Digital display, "Touch" keyboard, only 11mm thick and mounted on
The following can be selected from the control panel:
- Switching the device on and off
- The ventilation speed, in automatic or manual mode
- The room temperature
- The operating mode
The digital display also shows:
- Thermostat On / Off
- The room temperature / set temperature
- The ventilation speed with 3 positions displayed by graduated bar
- The operating mode
- The night-time comfort function (Sleep)
- Supervisor controlled operating mode (VMF-E5)
See the accessories manual for complete information on its features.
Example of a network with VMF-E5 supervisor consisting only of
VMF-E4
FCLI
MASTER
VMF-E4
FCLI + GLLI10N
FCLI + GLLI20N
in GLLI10N and GLLI20N grille units, and for all other VMF range
thermostats.
a single or networked fan coil (see characteristics of the combined
thermostat)
the wall in Type 503 recessed electrical boxes and compatible with
the Type 502 boxes, M20 (see installation manual).
(Automatic / Heating / Cooling)
FCLIs
MASTER x
VMF-E4
MASTER 3
MASTER 2
FCLI + GLLI10N
FCLI + GLLI10N
FCLI + GLLI20N
FCLI + GLLI20N
FCLI + GLLI10N
FCLI + GLLI10N
FCLI + GLLI20N
FCLI + GLLI20N
Example of a network with VMF-E5 supervisor consisting only of
mixed fan coils
MASTER x
VMF-E4
VMF-E4D
MASTER 2
MASTER 3
FCLI + GLLI10N
FCX + VMF-E1
FCLI + GLLI20N
FCXI + VMF-E18
FCL + GLL10N
FCL + GLL20N
FCLI + GLLI10N
FCX + VMF-E1
FCLI + GLLI20N
FCXI + VMF-E18
FCL + GLL10N
FCL + GLL20N
VMF-E5
VMF-E4
VMF-E4
MASTER 1
FCLI + GLLI10N
FCLI + GLLI20N
FCLI + GLLI10N
FCLI + GLLI20N
VMF-E5
VMF-E4
VMF-E4
VMF-E4D
VMF-E4D
MASTER 1
FCLI + GLLI10N
FCLI + GLLI20N
FCL + GLL10N
FCL + GLL20N
FCLI + GLLI10N
FCLI + GLLI20N
FCL + GLL10N
FCL + GLL20N