Gedore Dremotest E 8612-012 Manual De Instrucciones página 17

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
EN
WARNING
ALWAYS verify that the torque tester is properly fastened
prior to using the torque tester.
Make sure that you are ALWAYS using the unit according to
specification.
NEVER use the torque tester beyond the permissible torque
range. The torque range is imprinted beneath the display.
ALWAYS put the torque wrench on the adaptor at a 90°
angle.
NEVER use extensions.
ALWAYS use original accessory parts approved by the
manufacturer.
If the resistance changes unexpectedly in the course of
testing, IMMEDIATELY disengage the torque tester or the
torque wrench and check the torque tester and the torque
wrench for damage.
ALWAYS apply the torque tester in the direction of rotation
specified. Follow the direction of rotation arrow.
The torque tester displays the torque applied until a drop in
the torque occurs (e.g. due to the release of the torque
wrench or the disconnection of the power flow).
The maximum torque attained, prior to the drop,
is reproduced for a brief moment in the display. Then the
torque that is currently being applied is displayed again.
17