Care and Cleaning
To clean, wipe down with a damp cloth and towel dry.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
Troubleshooting
NOTE: Refer to the service parts section in this manual for
a detailed drawing showing the location of the parts listed
below.
Problem
There are leaks from the
handle.
The aerator has an
irregular or reduced
water ow.
The water will not shut off
completely.
Leaking from sink drain
at the base of the sink.
Possible Cause
The bonnet nut has come loose and/or the
washer is dirty or damaged.
The aerator is dirty or mis- tted.
The rubber seat and spring is dirty or
broken.
Rough or irregular surface on sink.
8
Solution
Tighten the bonnet nut.
Clean or replace the washer.
Remove the aerator and
check for debris.
Ensure that the rubber washer
is properly installed.
Remove the cartridge to check
the rubber seat and spring.
Clean or replace.
Apply additional silicone sealant
to the beveled side of the drain
ange.
Retighten and test for leaks.