3
9.3 Technical data
Designation
Filter
Filter stages
Filter method
Cleaning method
Filter surface m² [inch²]
Number of filter elements
Total filter surface m² [inch²]
Type of filter
Filter material
Filter efficiency ≥ %
Welding fumes class
IFA test standard
Filter class/Dust classification
Basic data
Extraction capacity m³/h [cfm]
Vacuum Pa [inch wc]
Motor power kW [hp]
Power supply/rated current/
protection type/ISO class
Permissible ambient temperature
°C [°F]
Duty cycle %
Noise level dB(A)
Compressed air supply bar [psi]
Compressed air
requirement/compressed air class
Basic product dimensions WxHxD
Basic product weight kg [lbs]
Additional information
Fan type
42,0410,2736-00; 1502940-00
Type
Safe Change Filter (SCF)
Tab. 17: Technical data
- 73 -
Exento LowVac
2
Disposable filter
--
25 [38750]
1
25 [38750]
Non-woven polyester
99.5
W3
DIN EN ISO 21904-1+2
E12
1,100 [647]
2,250 [9.04]
1.5 [2.04]
See name plate
-10 to +40 [+14 to +104]
100
70
--
--
See dimension sheet
127.0 [280.0]
Radial fan
EN