Programming Overview
3-9
Menu-
No.
Entry
Selection
point
5
Key switch function (J7)
0*
Open/Close pulse input
1
Block control panel
2
Block external control elements
3
Block control panel and external control elements
50
4
Activating the control elements for 10 secs.
5
Switch to dead man's Close
6
Switch to half opening of the door
7
Pulse input for Open-Stop-Close
Pulse input for Half Open-Stop-Close
8
9
AR - automatic closing
10
Pulse input for (smoke-heat exhaust) (menu 55)
Function of external impulse generators
0*
off
1
Dead man OPEN / Dead man CLOSE
2
Impulse OPEN / Dead man CLOSE
51
3
Impulse OPEN / Impulse CLOSE
4
Impuls 1/2 Öffnung / Impuls Zu
5
AR - automatic closing
AR - automatic closing, half opening
6
Open-close operation
7
52
001-256
Entering the control address
Module
off
0*
53
DC-module
1 - 4
Wireless closing edge, RadioSafe JCM
5
6
W-LAN module
Expansion control
54
off
0*
1, 2, 3
Actuation profiles, see extension control
55
Door setting for smoke-heat exhaust position
- -
Exit menu
6
Programming the START button on the transmitter
60
Programming button for 1/2-opening on the transmitter
61
Programming the light button on the transmitter
62
63
Deleting radio codes (press for 5 sec.)
Start button operating mode
0*
off
1
Impulse open-stop-close
64
AR - automatic closing
2
Open-close operation
3
- -
Exit menu
* Factory defaults
Menu
30-
37
(J1)
Item
1x
Menu-
No.
Entry
Selection
point
7
Soft start at reduced torque
70
0
off
1 - 13
Time (60mS – 300mS, in 20mS increments)
0 - 40
Run-out distance before top end position (0-40cm, 10*)
71
0 - 20
Reduced torque (16*)
72
- -
Exit menu
Motor brake
78
Type A, in preparation
Type B, in preparation
9
Selecting the door's service intervals
0*
no service interval
1
10000 cycles
2
20000 cycles
3
30000 cycles
4
40000 cycles
90
5
50000 cycles
6
60000 cycles
7
80000
cycles
8
100000
cycles
9
120000 cycles
10
150000 cycles
11
200000 cycles
12
250000 cycles
91
Issue of cycles counter
96
Issue of operating hours counter
97
Issue of error memory
98
Issue of software version
Resetting of factory setting (press for 5 sec.)
99
- -
Exit menu
70
72
Recommended adjustments
Menü 70
Soft start
Soft stop
Menü 71
Menü 72
Reduced torque
Enter
-
-
cycles
-
hours
-
-
hours
error code
-
-
serial-no.
date
71
2
2
10
10
3
6
GB
Exit
-
-
-
1
10
1