The machine is programmed to show some alarm messages on the display.
BOILER LEVEL (FILLING) TIMEOUT
When the following message is shown on the display:
FILLING
TIMEOUT
NO VOLUMETRIC COUNTER PULSES (5 SECONDS)
When the following message is shown on the display:
YYYYYYY
UNIT X V.C. ALARM
= it means that the time (by default set to 120 seconds) to fill the boiler up to level with
water has run out.
Whenever the level sensor detects no water in the boiler, filling is enabled.
If the boiler is not filled within 120 seconds (set by the technician), this alarm is shown
on the display, all the main dosing functions are deactivated, the pushbutton panels are
disabled and all the functions of the actuators are deactivated.
All the LEDs on the pushbutton panels start flashing to visually indicate to the user that
the machine has gone into alarm.
To exit from the alarm condition, turn the machine off and on again.
= YYYYYYY: indicates what is being dispensed (espresso, long coffee, tea) at the time the
alarm is signalled.
X: indicates the unit in alarm (1, 2, 3, 4).
It means that no volumetric counter pulses are arriving at the activated unit (X).
If the dose in progress is not counted for each activated unit for more than 5
consecutive seconds, the LED relating to the dose selected starts flashing.
After one minute of no volumetric counter pulses, the dose in progress is
automatically stopped.
18,
ALARMS.
47