IMPIANTO IDRAULICO - PLUMBING SYSTEM - INSTALLATION HYDRAULIQUE - HYDRAULISCHE ANLAGE -
INSTALACIÓN HIDRÁULICA - ГИДРАВЛИЧЕСКАЯ СИСТЕМА - ΥΔΡΑΥΛΙΚΟ ΣΥΣΤΗΜΑ -
Technical data for the plumbing system:
- Working pressure: recommended operating field 2 ÷ 4 bar
- Maximum working pressure: 5 bar (Install a pressure reducer for higher hydraulic pressures)
- Maximum working temperature: 65°c
- Floor waste required with capacity ≥ 40 l/min.
- 4,7 kg empty weight of the complete head shower (with water about 5,3 kg)
Supply pipe to shower head [ A ]: minimum internal diameter 12mm
Static
pressure
[ bar ]
1
2
3
4
5
( * ) Minimum delivery from head shower for the correct working "Rain": 13 l/min [ B ].
Static
pressure
[ bar ]
1
2
3
4
5
Data for plant dimensioning
Minimum required feeding
for a correct working of the shower system*
Data for boiler and waste dimensioning
Maximum delivery for the shower system
fed with internal 12 mm Ø pipes
7
[ l/min ]
22,5
21,5
20,5
19,5
18,5
Rain Function [ B ]
[ l/min ]
14 [ with limiter ]
16 [ with limiter ]
16 [ with limiter ]
16 [ with limiter ]
16 [ with limiter ]
水力设备
ING