Teleco TVPLD868C150TT Manual Del Usuario página 12

Unidad de control 230vac con receptor radio para el control de un motor 24vdc para perfiles orientables - transformador integrado 120w
Idiomas disponibles

Idiomas disponibles

INDEX
1. Connections and adjustments
2. Transmitters
2.1 Radio codes memorization
2.2 Working time configuration (necessary if 7/42 channel transmitters are used)
2.3 Radio codes deletion
2.4 Remote memorization of other radio codes
2.5 Remote deletion of a radio code
3. Sensors
3.1 WIND sensor
3.2 RAIN sensor
3.3 SNOW condition
3.4 Activation/desactivation RAIN sensor or SNOW condition (rain+temp.)
4. Quick learning of limit switch
5. Technical specifications
1
CONNECTIONS AND ADJUSTMENTS
LR LA LM
DIP SWITCH P1
13
14
15
16
17
WARNINGS
p. 12
The product at issue must be installed, commissioned and maintained only by licensed and authorised
p. 13 - 15
people, respecting the laws concerning the automatic covers. All the connections must be rated for a
single-phase 230Vac power supply. For the disconnection from the power line, use an all-pole switch with
contacts having a dimension of at least 3,5mm. Arrange all the necessary safety devices and use only
materials complying with the standard of electrical installations. The cable must have a section properly rated
according to the load connected. Before the connection to the power supply make sure that the sensors and
motors are correctly connected. A faulty connection of the motors (polarity inversion) could damage them
together with the connected mechanical elements. Use a 2x1.5mm cable to connect the motors and the
p. 15 - 16
control unit for length up to 6m, or 2x2.5mm cable for longer segments. PRODUCT DISPOSAL: at the end
of this product's useful life, it must not be disposed of as domestic waste, but must be taken to a collection
centre for waste electrical and electronic equipment. Hereby Teleco automation s.r.l. declares that the
product complies with the essential requirements and other relevant provisions, established by the Directive
1999/5/EC. The declaration of conformity can be consulted on the web site: www.telecoautomation.com/ce.
In the view of a constant development of their products, the manufacturer reserves the right for changing
p. 16
technical data and features without prior notice.
p. 22
RN
AN
LED
LED
12
11
7
8 9 10
6
10
5
11
4
12
3
13
14
2
M
15
1
16
17
12
1
MOTOR (CLOSE)
2
MOTOR (OPEN)
3
RAIN SENSOR (YELLOW, GND)
4
RAIN SENSOR (BLUE, SIGNAL)
5
RAIN SENSOR (WHITE,+12V)
6
WIND SENSOR (BLUE)
7
WIND SENSOR (BROWN)
8
INPUTS COMMON
9
CLOSE/STOP INPUT (N.O.)
OPEN/STOP INPUT (N.O.)
AERIAL RF
AERIAL GND
TEMPERATURE SENSOR
TEMPERATURE SENSOR
230Vac POWER SUPPLY (LIVE)
230Vac POWER SUPPLY (NEUTRAL)
GROUND
If not used, close the terminals 13-14
with a bridge
AN LED
WIND SENSOR PULSES
RN LED
RAIN SENSOR ACTIVE
LA
FLASHING = WIND ALARM
FLASHING = TEMP. ALARM
LR
ON = RAIN ALARM
LM
LIMIT SWITCH LED
P1
PROGRAMMING BUTTON
MOTOR STOPS. The control unit stops the motors
at the point of a mechanical stop through current
absorption. The threshold can be set with DIP1
and DIP2 (table). Attention! Check that the motor
only stops at the mechanical stops (LM = ON):
increase the threshold if the motor stops during
operation or decrease if the motor continues to
push against the mechanical stops.
DIP1 DIP2
(A)
OFF
OFF
1
OFF
ON
2
ON
OFF
3
ON
ON
4
Default
loading