10
TLX LIVERPOOL SERIES
Amplifi er Considerations
LIVERPOOL series loudspeakers are optimized for use with LAKE LM series controllers and LAB GRUPPEN amplifi ers or LAB GRUPPEN DSP amplifi ers with
LAKE processing. A full range of DSP presets to suit a variety of confi gurations is provided for download on the TURBOSOUND website where limiters, crossover points,
corrective component time alignment and equalisation are pre-programmed to ensure optimum sound quality and long-term reliability. Use LAB GRUPPEN 'CAFE'
software - available for download from labgruppen.com - to determine the optimum amplifi er confi guration for your system. Parameters for the use of third party
amplifi cation and processing can be provided upon request.
LIVERPOOL series loudspeaker enclosures should be driven by high quality power amplifi ers designed for true professional use. The use of under powered
amplifi ers must be avoided as heavily clipped signals can cause permanent loudspeaker damage. For subwoofers, passive loudspeakers and low frequency, mid
frequency sections of multi-way active loudspeakers, amplifi ers should be capable of delivering power equal to twice the continuous power rating at the stated
nominal impedance. For the high frequency section of multi-way active loudspeakers, amplifi ers should be capable of delivering power equal to ten times the
continuous power rating at the stated nominal impedance.
Model
TLX43
Mode
Bi-amp LF
Impedance (ohms)
16
Continuous RMS
150
Power Handling (W)
Peak
600
Minimum Recommended Amplifi cation (W)
300
NOTE: Power 1x TLX215L or 2x TLX212L subwoofers per amplifi er channel (4 ohm load)
NOTE: Since TLX subwoofers are wired 1+/- = LF1||LF2; 2+/- = LINK, in order to power multiple TLX212L or TLX215L enclosures, it is advised to construct SUB LINK
cables wired: 2+ -> 1+ and 2- -> 1- . A single NL4 cable from LAB GRUPPEN bi-wired NL4 outputs (Channel 1 = 1+/-; Channel 2 = 2+/- or Channel 3 = 1+/-;
Channel 4 = 2+/-) connects to the fi rst TLX215L subwoofer then the SUB LINK cable jumps to the second TLX215L subwoofer, providing one TLX215L subwoofer per
amplifi er channel. For TLX212L, standard NL4 link cables can be used in conjunction with SUB LINK cables to power two TLX212L subwoofers per amplifi er channel.
Refer to wiring diagrams below for further details.
TLX 212L Example wiring guide
LAB GRUPPEN PLM+ Series
Amplifier outputs configured
in LAKE software for TLX212L
on pins 1 + / - and 2 + / -
NOTE: To use all 4 channels of a LAB GRUPPEN PLM+ Series Amplifier to drive 8 x TLX212L total, repeat for
channel 3,4 outputs and ensure correct output routing in LAKE software.
TLX212L
TLX84
Bi-amp HF
SUB
Bi-amp LF
Bi-amp HF
16
8
16
16
30
800
450
60
120
3,200
1,800
240
300
1,600
900
600
SOLID
NL4 - NL4 four-conductor cable with standard wiring
(1+/- to 1+/- and 2+/- to 2+/-)
THIS NL4 USES
THIS NL4 USES
PINS 2+ / 2-
PINS 1+ / 1-
DASHED
NL4 - NL4 two-conductor "SUB LINK" cable cross wired from 2+ to 1+ and 2 - to 1-
Connections
Mode
Back Panel
TLX43
TLX212L
TLX215L
SUB
4
1,000
4,000
2,000
TLX84
TLX215L
TLX 215L Example wiring guide
LAB GRUPPEN PLM + Series
Amplifier outputs configured
in LAKE software for TLX215L
on pins 1 +/- and 2 +/-
Connector
BI-AMP, Input Low +
NL4
Amplifier Channel 1
Input/
Link
1+
1-
BI-AMP, Input Low -
BI-AMP, Input High +
2-
2+
Amplifier Channel 2
NL4
Input/
BI-AMP, Input High -
Link
Input SUB +
NL4
Input/
Link
1+
1-
Input SUB -
2-
2+
NL4
Input/
Link
BI-AMP, Input Low +
Amplifier Channel 1
1-
1+
NL4
BI-AMP, Input Low -
Input/
Link
BI-AMP, Input High +
2-
2+
Amplifier Channel 2
BI-AMP, Input High -
NL4
Input/
Link
Input SUB +
NL4
Input/
Link
1-
1+
Input SUB -
2-
2+
NL4
Input/
Link
SOLID
NL4 - NL4 four-conductor cable with standard wiring (1+/- to 1+/- and 2+/- to 2+/-)
THIS NL4 USES
PINS 2+ / 2-
DASHED
NL4 - NL4 two-conductor "SUB LINK"
cable cross wired from 2+ to 1+ and 2 - to 1-
THIS NL4 USES
PINS 1+ / 1-
NOTE: To use all 4 channels of a LAB GRUPPEN PLM+ Series Amplifier to drive 4 x TLX215L total, repeat for
channel 3,4 outputs and ensure correct output routing in LAKE software.
Quick Start Guide
11
Internal Schematic
>
1+
>
1-
+
2+
>
HF
-
2-
>
+
>
1+
LF 1
-
1-
>
2+
>
2-
>
+
-
LF 2
+
>
1+
-
LF 1
>
1-
2+
>
2 -
>
+
>
1+
LF 2
-
>
1-
2+
>
2 -
>
+
-
HF 1
>
1+
>
1-
+
>
2+
HF 2
-
2 -
>
+
>
1+
-
LF 1
>
1-
>
2+
2 -
>
+
-
LF 2
+
>
1+
-
LF 1
1-
>
2+
>
2 -
>
+
>
1+
LF 2
-
1-
>
2+
>
2 -
>