FUXTEC FX- DS5L Manual De Usuario página 10

Idiomas disponibles
  • ES

Idiomas disponibles

Original-Bedienungsanleitung FUXTEC Drucksprüher 5l_8l_rev01
Troubleshooting
The pump is pressurized but does not emit any liquid:
a) Check whether the filter and the nozzle of the spray lance are clean and clean if necessary.
No pressure is building up on the pump:
b) Activate the pump lever several times while the spray lance is closed and then open the pray
lance.
c) When a little fluid is in the container, activate the pump lever until a certain resistance is felt.
d) Check whether all closures are tightly screwed.
e) Check whether the seals are intact. Replace if need be.
Technical Data
Max. filling quantity
Total volume
Admissible operating pressure
Max. volume flow
Admissible operating
temperature
Spraying figure
Bore
Recoil energy at jet
Spraying angle
:
5 Liter
:
8,0 Liter
:
2,5 bar
:
1,5l/min, 2,5 bar
:
1°C – 30°C
:
Hollow cone
:
1,3 mm
:
<20N
:
35°
10
loading

Este manual también es adecuado para:

Fx- ds8l