Dandy Simplicity SPAC8499 Manual Del Propietário página 22

Idiomas disponibles

Idiomas disponibles

Air Conditioner Operating Instructions
(cont'd)
5) Press the FAN key to select the desired fan
speed setting (Low-Med-High). See Fig. 14.
Your selection will be displayed in the LCD
window (each depression of the fan key will
advance to a different setting).
6) Press the SWING key to activate the automatic
air swing (oscillating) feature (the "air swing"
symbol will appear in the LCD window). Fig. 15.
To deactivate the air swing feature, press the
SWING key again.
7) Condensed water will be accumulated in the
water tank. When the tank is full, the unit will
sound a signal (8 beeps) and the Water Full
indicator light start flashing. At this time the air
conditioning process will immediately stop.
However, the fan motor will continue to operate
(this is normal). Carefully remove the water tank
from the cabinet and dispose of the water.
Replace the water tank back to it's original
position (in cabinet) and the air conditioning
process will automatically resume. It may take
3-5 minutes for the compressor to re-start. This
is normal.
8) To adjust "air flow" direction, (up / down only)
adjust any one of the Horizontal Louver Blades
(excluding the top or bottom louver) and the
remaining louvers will automatically adjust to the
set position (excluding the top and/or bottom
louvers). Fig. 16.
Cooling stops automatically when the set
temperature is achieved. Cooling resumes when the
room temperature rises above the set temperature
level. The temperature has no effect on the fan
operation. Therefore, the fan will operate
continuously (after the compressor has cycled off) to
maintain optimal temperature control.
CAUTION
During air conditioning and dehumidifying modes, if the
compressor cycle is interupted (unplugged, power
failure,etc.) and reinstated immediately thereafter, (within
3-5 minutes) a "compressor protection circuit" is
automatically self-affected. The mode indicator light will
flash "green" for approximately 10 seconds, confirming the
protection circuit is activated. The compressor cannot
operate during a "compressor protecton" condition. (this is
normal) It may take 3-5 minutes before the "protection
circuit" self-deactivates.
DO NOT ATTEMPT TO START THE UNIT
(COMPRESSOR) DURING THIS PERIOD.
Upon re-starting the unit (turn 1/0 switch on) all
program information(i.e. time, mode, fan speed, auto
timed programs) will have to be re-set.
TIMER
ON
Water Full
MODE
COOL
FAN SPEED
HIGH
TEMP.
Cool/Heat/Dry
Fan Speed
TIMER
ON
Water Full
MODE
COOL
FAN SPEED
HIGH
SWING
TEMP.
Cool/Heat/Dry
Air Swing
Removal and/or partial displacement of the water
tank will cause the compressor to stop operating
(this is a safety feature). This condition will cause
the unit to "beep 8 times" and the "water full" light
will flash (red) continuously until corrected. The
compressor cannot operate during a flashing
"red" light condition. Check the following;
1. Is the water tank full?
Empty and re-install water tank.
2. Has the water tank been accidently displaced?
Re-position water tank.
The "red" light will stop flashing automatically
when the water tank has been emptied and/or
correctly re-positioned.
10
I/O
MODE
12:00
FAN
ON
TIMER
00
OFF
SWING
I/O
MODE
12:00
FAN
ON
TIMER
00
SWING
OFF
ATTENTION
TEMP./CLOCK
ADJ.
CLOCK
Fig. 14
TEMP./CLOCK
ADJ.
CLOCK
Fig. 15
Fig. 16
loading