1.
This appliance has been designed to be used exclusively with the gases indicated in the technical data table.
2.
This product has been designed to be used with 15 kg gas cylinders. The maximum cylinder dimensions must not exceed the diameter
of 30 cm and the maximum height of 65 cm.
3.
The "65411" model requires the use of hose and regulator, contact the supplier to check this.
4.
The "65411TR" model includes the hose and regulator. Use only the hose and the regulator that are supplied (50cm hose and pressure
regulator). In case of replacement, contact the manufacturer.
5.
Always check that the cylinder complies with the regulations and that the due date has not been exceeded. The use of old or expired
cylinders can pose a serious risk. Never use cylinders whose valves are damaged.
6.
Avoid bending or twisting the gas hose.
7.
Always check that the hose is in good condition and that its due date has not been exceeded. In case of doubt, it is preferab le to
contact a specialised technician to have it replaced.
8.
Never connect the appliance to the cylinder without using a pressure regulator.
9.
Always close the cylinder valve when the appliance is not being used.
WA R NI N G :
This appliance always requires a gas regulator. Should it be necessary to replace the one that is supplied, contact the
supplier. The connection to the cylinder must be carried out in a room free of flames. Do not smoke during the connection operations.
Before connecting the cylinder, check that the heater switch is closed.
A. Take the catalytic heater off the box
B. Remove all the protective packaging used for transport.
C. Check that the heater has not been damaged during transport. Should it be damaged, contact the retailer where the product was
purchased.
D. Remove the rear panel.
E. Connect the hose and the regulator to the appliance.
F. Connect the regulator to the gas cylinder.
G. Perform the test to check for possible leaks (follow the instructions below)
H. Place the gas cylinder inside the cylinder holder housing, avoiding twisting the hose.
I. Close the rear panel.
ATTENTION: The lifted support (art. 65411ACC) is necessary only and exclusively in case of tank is not provided with a compatible
diameter with the gas cylinder compartment.
Mounting instructions:
Access to housing cylinder holder.
Put the floor on one side (Fig A) and then place it to the surface of compartment (Fig B).
Check the solidity of the supporting surface.
Verify compatibility of the height of the cylinder.
WA R NI N G :
Before performing the test, extinguish all the flames and turn off all the electrical appliances. Do not smoke while checking
for gas leaks.
1. This test must be performed outdoors or in well ventilated rooms.
2. Check that the cylinder valve is closed.
3. Prepare a solution of water and soap using equal amounts of each of them or use Revelgas art.1726
4. Using a brush, apply the solution on the joints between the cylinder, the regulator and the heater.
5. Open carefully the valve.
6. If there are gas leaks, bubbles will be formed in the points corresponding to the leaks. CLOSE THE CYLINDER VALVE. If there is a
leak, tighten all the joints and repeat the test. Should the leak continue, contact the supplier immediately.
WARNING: Do not turn the appliance on if gas is smelt. Extinguish all flames. Ventilate the room. Move the heater outside or in a
very well ventilated place and check for possible gas leaks, following the procedure indicated in this manual.
Never use tools or devices to press the hand wheel. In case of using a new gas cylinder for the first time, after having opened the gas tap,
wait around 1 minute before moving on to point 2. Should the hand wheel remain jammed after it has been held down, never try to
unblock it using tools or devices. Contact a qualified technician.
DT Istr (65411)– Rev 10 02/2019
GAS REQUIREMENTS
INSTALLATION
Fig. A
CHECKING FOR GAS LEAKS
OPERATION
Fig. B
9