Mercalor MT01559 Manual De Instrucciones página 29

Idiomas disponibles

Idiomas disponibles

WARNING! A leak test must be performed annually and each time a cylinder is hooked up or
if a part of the gas system is replace.
WARNING! Never use an open flame to check for gas leaks. Be certain no sparks or open
flames are in the area while you check for leaks. Sparks or open flames will result in a fire or
explosion,damage to property,serious bodily injury,or death.
Leak testing: this must be done before initial use,annually,and whenever any gas
components are replaced or service. Do not smoke while performing this test,and remove all
sources of ignition. See Leak Testing Diagram for areas to check. Turn all burner controls to
the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the
regulator,hose,manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with
one recommended by the Customer Care department and have the patio heater inspected by
a certified gas installer
If the leak cannot be stopped,immediately shut off the gas supply,disconnect it,and have the
patio heater inspected by a certified gas installer or dealer. Do not use the patio heater until
the leak has be corrected.
LEAK CHECK
29
loading