To Replace Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Set the On/Auto/Off lever to
"OFF" and unplug unit.
3.
Remove the outlet pressure
gauge and
adapter
regulator.
Regulator
4.
Remove the regulator.
5.
Apply pipe sealant tape to the
nipple.
from the
Outlet
Pressure
Gauge
Adapter
Nipple
19- ENG
6.
Assemble the regulator and
orient as shown.
Regulator
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
Regulator
Arrow
7.
Reapply pipe sealant to outlet
pressure gauge and adapter.
8.
Reassemble outlet pressure
gauge and adapter. Orient outlet
pressure gauge to read correctly.
Tighten quick connect with
wrench.
A00844