8.- AUDIO ALARM OUT: line output for paging from remote microphone ZS-11, the microphone inputs
MIC 1/2 or the audio inputs LINE 1/LINE 2 when the contacts ALARM IN A/B are closed..
9.- LINE 1/LINE 2 IN: line inputs for alarm paging. These inputs are activated when the ALARM IN A/B
contacts are closed. The priority level of the different inputs is as follows: LINE IN 2 -> MIC 1/2 -> LINE
IN 1, 10 kΩ euroblock connectors.
10.- MIC 2: unbalanced microphone input with 6.3 mm jack connector, 600 Ω.
11.- ALARM IN A/B: alarm input contacts. When these contacts are closed the audio line inputs LINE 1/
LINE 2 will be activated and all the zones will be activated for paging.
12.- ALARM OUT A/B: alarm output contacts. These contacts close automatically when the ALARM IN A/B
input contacts are closed.
NOTE: if you have more than one ZSC-1110 zone system, it is recommeded that the ALARM OUT A/B
output is connected to the ALARM In A/B input of the following zone system.
NOTE: when used in conjunction with the ZS-1112R and ALARM-IN function, the attenuator priority will
not be automatically turned off when ALARM-IN is turned off. The priority of the attenuators must be reset
manually by switching the device off and on after ALARM-IN.
INSTRUCTIONS FOR USE
CONNECTION OF ZS-11 MICROPHONE
In order to connect the ZS-11 microphone, Cat 5e type control cable is used. This cable is connected to the
COM socket on the zone system ZSC-1110 and on the COM socket of the first microphone ZS-11.
In the event of having more than one microphone, these can be connected to each other by connecting the
COM connector of the first to the COM connector of the second.
ZSC-1110
CAUTION: SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
CHIMES
The chimes can be used in two ways.
-
Chimes can be played remotely via the microphone ZS-11. Select the zone or zones in which you wish
to page using the corresponding zone selction buttons. Then press the CHIME ON button to broadcast
the chimes.
-
To play the chimes from the zone system, select the zones in which you wish to page by pressing the
MUSIC/PAGING button (the LED indicator should light up in red) and then press the buttons of the
required zones (the LED indicator of each zone will light up in red or orange repectively, depending if the
background music is deactivated or activated). Then press the CHIME button to broadcast the chimes
in the selected zones.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
~230 V AC. 50/60 Hz, FUSE: T1AL 250 V
POWER CONSUMPTION: 40 W
ZSC-1110
ZONE SYSTEM
CHIME
BASS
TREBLE
DEVICE ID
COM
VOL
ZS-11
POWER
POWER
24 V DC, 2 A
COM
OUTPUT
PAGING MICROPHONE
ZS-11
POWER
POWER
24 V DC, 2 A
COM
OUTPUT
PAGING MICROPHONE
- 4 -
MIC 2
AUDIO
ALARM
OUT
LINE IN
MIC VOL
CHIME VOL
LINE IN
MIC VOL
CHIME VOL