Installation (continued)
INSTALLING THE DAMPER
(SKIP THIS STEP IF YOU ARE NOT USING A RECTANGULAR DUCT)
NOTE:
Only install the damper if you are using a venting system that does not
already have a damper.
If this hood replaces an existing unit, the location of the air exhaust can
vary from one manufacturer to another. Ensure that the damper fits in the
existing opening before installing.
- Install the damper (B) either in the top opening (3) for top
venting or in the back opening (4) for back venting .
- Insert the damper (B) into the chosen opening in the range
hood (A), ensuring that the central flap (6) goes into the
opening while the two side flaps (7) remain above it.
- Lift the lid (8) of the damper and screw the damper (B) to
the range hood (A) with the two short tapping screws (BB) .
- Seal the damper (B) to the range hood (A) on all four sides
with duct tape .
INSTALLING THE ROUND DUCT
(SKIP THIS STEP IF YOU ARE NOT USING A ROUND DUCT)
- Install the round duct (C) in the top opening (5) for top venting .
- Screw the duct (C) to the range hood (A) with the four short
tapping screws (BB) .
- Seal the round duct (C) to the range hood (A) on all sides with
duct tape .
BB
A
8
BB
3
B
A
11
Please contact [email protected] or 1-877-333-0098 for further assistance.