Installation Notes - Pooxtra Pure Sine Wave Serie Manual De Usuario

Inversor de potencia de onda sinusoidal pura; inversor de potencia de onda sinusoidal modificada
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION NOTES

WARNING: Ensure ventilation when using batteries. Batteries may generate
flammable gas during charging or discharging.
The inverter has four mounting holes in its mounting bracket that allow the unit to
be fastened against a bulkhead, floor, wall or other flat surface. Ideally, the mounting
surface should be cool to the touch. It is more electrically efficient to use longer AC
wiring than DC wiring, so install the inverter as close as possible to the DC power source.
The inverter can be operated in any position, however, if it is to be mounted on a
wall, mount it horizontally (fig 4a) so that LED dispaly ,switches, outlets and terminal
blocks located on the front panel are visible and accessible. Do not mount on wall
in positions shown in figs. 4 (b) & 4(c). If the inverter is to be installed in a moving
vehicle, we strongly recommend that the inverter be shock-mounted either on the
floor (in a clear, safe area) or on a secure flat surface.
(a)
(b)
(c)
Fig.4 Mounting arrangement on wall
CAUTION
(For 12V DC INPUT Inverter)
The power inverter must be connected only to batteries with a nominal output
voltage of 12 V. The unit will not operate from a 6 Volt battery, and will sustain
permanent damage if connected to a 24 V battery.
CAUTION
Loose connectors may cause overheated wires and melted insulation. Check to
make sure you have not reversed the polarity. reverse polarity connection will result
in a blown fuse and may cause permanent damage to the inverter.
Damage due to reverse polarity is not covered by warranty.
TM
www.pooxtra-inverter.com