Caution:
Removing the stickers can damage the mirror
surface.
Blocking the curtains
See Figure 23.
The mirror blinders are fitted on the mirror by default. To
remove a blinder, first remove the interior part of the detector.
Then lift the lower part of the blinder and wiggle the upper part
to loosen it. When long-range detection is not required (>20 m /
65.6 ft.), remove the long-range mirror (Figure 24).
Pry-off and cover tamper
The detector has both pry-off and cover tamper (EN 50131-2-
2 compliant).
It is important to use the screw indicated in Figure 4 in order to
ensure pry-off tamper.
For corner-mount applications, the pry-off tamper cannot be
activated.
Pry-off tamper is not evaluated by UL.
SB01 swivel-mount bracket (optional)
When it is not possible to mount the detector on a wall, use the
SB01 to mount it on the ceiling.
See Figure 26.
SB01 swivel-mount bracket is not evaluated by UL.
Glossary
Alarm memory. A storage medium located on the detector that
can record signals generated by the detector.
Curtains. A vertical continuous layer of detection zones. The
PIR detector can only detect motion within the curtains
and not in the spaces between them.
Curtain Location Mode (CLM). A feature of the detector that
identifies precisely the edges of the curtains.
Day mode (disarmed mode). The detector is not required to
generate an alarm signal or message when activated by
a person walking in front of it.
Night mode (armed mode). The detector generates an alarm
signal or message when activated by a person walking in
front of it.
Self test. The detector itself monitors the sensor and
associated on-board signal processing circuitry.
Technical fault (TF). The fault signal or message that is
generated on the trouble relay when the detector suffers
a fault.
Walk test. An operational test done by the installer to see if the
equipment will generate an alarm.
Specifications
Input power
Peak-to-peak ripple
Current consumption:
Normal operation
Alarm
P/N 145797999-2 (ML) • REV G • ISS 20DEC18
9 to 15 V
(12 V nominal)
For UL/cUL installations: 10 to 15 V
(12 V nom.)
2 V (at 12 V )
11 mA (for UL/cUL installations
0.132 W)
9 mA
Maximum
Mounting height
Target speed range
Alarm output
Tamper output
Trouble output
Alarm time
Detector start-up time
Operating temperature
Relative humidity
Dimensions
(H x W x D)
Weight
Number of curtains
Viewing angle
IP/IK rating
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092,
USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers
and product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
UL compliance
The units are intended to be connected to
a Listed Burglar Alarm Control Unit or Listed
Burglar Alarm Power Supply, that provides
a minimum of 4 hours Standby Power.
The installer should perform walktest at least
ones a year.
Use only a listed power-limited supply.
ICES-003
VE73x: This Class B digital apparatus complies
with Canadian ICES-003.
15 mA
1.8 to 3.0 m (5.9 to 9.8 ft.)
20 cm/sec to 3 m/sec (7 in./sec to
10 ft./sec)
80 mA at 30 V
max., resistive
80 mA at 30 V
max., resistive
80 mA at 30 V
max., resistive
3 sec
50 sec
−10 to +55°C (14°F to 130°F)
For UL/cUL installations:
0 to 49°C (32 to 120°F)
95% max.
(UL/cUL installations)
175 x 93 x 66 mm
(6.88 x 3.66 x 2.60 in.)
275 g (9.70 oz.)
1X 60 m, 5X 20 m, 4X 18.5 m, 2X 18 m
(1 at 197 ft., 5 at 65.6 ft., 4 at 60.7 ft.,
and 2 at 59 ft.) See Figures 21 and 22.
UL639:
11 at 20 m and 1 at 55 m
(11 at 65.6 ft. and 1 at 180 ft.)
86° at 20 m and 3° at 60 m
IP30 IK02
or scan the QR code.
9 / 48
loading

Este manual también es adecuado para:

Ve700 serie