Actuador pulsador/de conmutación eNet, enchufable
Switch-on delay
Switch-off delay
Run-on time
Manual switch-off of the run-
on time
82592213
J0082592213
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
On, Off
Basic setting: Off
6/10
The load switches on after a
delay. Repeated switch-on
commands restart the delay ti-
me. If the load has not yet
been switched on due to the
delay when a switch-off com-
mand comes, then the load
will remain off.
In Flashing operating mode,
the pause time is set using
this parameter.
Comment: The set times apply
to operation using radio trans-
mitters. The relay is switched
immediately when the Prog
button is pressed.
The load switches off after a
delay. Repeated switch-off
commands restart the delay ti-
me. If the load has not yet
been switched off due to the
delay when a switch-on com-
mand comes, then the load
will remain on.
In Flashing operating mode,
the pulse times are set using
this parameter.
Comment: The set times apply
to operation using radio trans-
mitters. The relay is switched
immediately when the Prog
button is pressed.
As soon as a run-on time has
been entered, the actuator will
no longer remain on perma-
nently, but only for the length
of the run-on time. The run-on
time is restarted if actuation is
repeated. This parameter is di-
rectly connected to the "Ma-
nual switch-off of run-on time"
parameter.
Comment: The set times apply
to operation using radio trans-
mitters. The relay is switched
immediately when the Prog
button is pressed.
Allows manual switch-off of a
running run-on time. If the pa-
rameter is switched off, then a
switch-off command will also
switch the actuator on. This
parameter is directly connec-
ted to the "Run-on time" para-
meter.
24.03.2017