PLACING THE MACHINE IN SERVICE
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: FACOM N.580.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
through the machine's inlet connection.
3
Model
Pad
mm
V.260F
100 x 180
Model
Free speed
rpm
V.260F
8500
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
PRODUCT V.260F – FACOM PNEUMATIC VIBRATING SANDER
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD 11148-8: 2011
EN ISO 12100:2010
EN ISO 15744:2008
EN ISO 28927-3:2009
LUBRIFICATION
1
3a
Orbit
Pressure dB(A)
mm
5
95,2
Air
consumption
l/min
115
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
3b
Noise level
Power dB(A)
k*
3
106,2
Working
Weight
pressure
bar
kg
6,2
2,1
288 x 198 x 118
EMERGENCY
GATE VALVE
2
4
Pressure dB(C)
k*
k*
3
96,1
3
Dimensions
mm
20.01.2010
F
ACOM QUALITY MANAGER
Vibrations level
m/s
2
k**
53,8
5,82