Contact the Technical Assistance service for all other
interventions.
Use only original spares.
Should the power cable be damaged, it must be
replaced by a cable or a set of special cables avai-
lable from the manufacturer or its assistance service.
The pins and joints of the connection cables of the
electrical system must be protected against accidental
water sprays.
Cleaning/inspecting the strainer
Expose the strainer (2 - Fig.19) in the machine water
inlet connection by removing the inlet connector
(1). The strainer (2 - Fig.19) can be easily removed
with longnose pliers. Rinse and replace. If damaged
replace.Never use the pressure washer without the
straineror a damaged strainer.
Checking Pump Oil.
From time to time check the oil level in the high
pressure pump by means of the sight glass or the
dipstick.
If the oil has a milky appearance, call the technical
service centre immediately.
TABLE OF ROUTINE MAINTENANCE
Description of operations:
Check power cable - pipes - high pressure
connectors
Ist oil change in H.P. pump
Subsequent changes
in H.P. pump
Clean water filter
STORAGE
Store the appliance in premises protected against
freezing conditions.
If freeze protection is not guaranteed, suction a
glycol based anti-freeze into the pump, as for cars
- Immerse the water pipe into the container of anti-
freeze
- Immerse the gun without the sprayer nozzle into
the same container
- Insert the appliance with open gun
- Activate the gun until an even jet is obtained.
- Store the rest of the anti-freeze in a closed con-
tainer.
Each use
After 50 hours
Every 500 hours
Every 50 hours
18
Treatment of waste from electric/electronic
equipment
Dispose of the product in accordance with current
regulations concerning differentiated waste disposal
in dedicated waste disposal areas. Do not treat as
simple urban waste.
For any information please contact the manufacturer
at the address specified in the user manual.
The product complies with the requirements
of the new directives introduced for the envi-
ronmental safeguard and must be disposed
of appropriately at the end of its life cycle.