8.12 Adjusting the laser (fig. 18)
If the laser (32) ceases to indicate the correct cutting
line, you can readjust the laser. Loosen the Philips
head screws (D) and set the laser by moving side-
ways until the laser beam strikes the teeth of the saw
blade (6).
Firmly secure both screws (D).
8.13 Changing the speed (fig. 17)
The mitre saw has 2 speed ranges:
• To operate the mitre saw at a speed of 3200 rpm
(metal), set the speed regulation switch (34) to po-
sition I.
• To operate the saw at a speed of 5000 rpm (wood),
set the speed regulation switch (34) to position II.
9. Transport
• Tighten the locking handle (11) to lock the rotary
table.
• Press the machine head (4) downwards and secure
with the locking bolt (23).
• Fix the saw's drag function with the locking screw
for drag guide (20) in rear position.
• Carry the equipment by the fixed saw table (15).
• When reassembling the equipment proceed as de-
scribed under section 7.
10. Maintenance
m Warning! Prior to any adjustment, maintenance or
service work disconnect the mains power plug!
General maintenance measures
Wipe chips and dust off the machine from time to time
using a cloth. In order to extend the service life of the
tool, oil the rotary parts once monthly. Do not oil the
motor.
When cleaning the plastic do not use corrosive prod-
ucts.
Cleaning the moving saw blade guard safety de-
vice (5)
Always check the saw blade guard for debris before
using the machine.
Remove old sawdust and splinters using a brush or
similar tool.
Replacing the table insert
Danger!
With a damaged table insert (10) there is a risk of
small parts getting stuck between table insert and
saw blade, blocking the saw blade.
32 | GB
Immediately replace damaged table inserts!
1. Remove screws at table insert. If required, turn
rotary table and incline saw head to be able to
reach the screws.
2. Remove table insert.
3. Install new table insert.
4. Tighten the screws at table insert.
Brush inspection (fig. 19)
Check the carbon brushes after the first 50 operat-
ing hours with a new machine, or when new brushes
have been fitted. After carrying out the first check,
repeat the check every 10 operating hours.
If the carbon is worn to a length of 6 mm, or if the
spring or contact wire are burned or damaged, it is
necessary to replace both brushes. If the brushes are
found to be usable following removal, it is possible to
reinstall them.
When servicing the carbon brushes, open the two
latches counterclockwise (as shown in figure 19).
Then remove the carbon brushes. Replace the car-
bon brushes in the reverse order.
11. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
12. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavourable conditions in the power supply
the product can cause the voltage to fluctuate tem-
porarily.
• The product is intended solely for use at connec-
tion points that
a) do not exceed a maximum permitted supply im-
pedance "Z" (Zmax = 0.382 Ω), or
b) have a continuous current-carrying capacity of
the mains of at least 100 A per phase.