If you do not want to use the cooler for a longer period of time:
➤ Leave the lid slightly open. This prevents odor build-up.
5.9
Defrosting the cooler
Humidity can form frost in the interior of the cooler or on the evaporator. This
reduces the cooling capacity.
A
NOTICE! Damage hazard
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
To defrost the cooler, proceed as follows:
1. Take out the contents of the cooler.
2. If necessary, place them in another cooling device to keep them cool.
3. Switch off the device.
4. Leave the lid open.
5. Wipe off the defrosted water.
5.10
Replacing the AC fuse
D
DANGER! Electrocution hazard
Failure to obey this warning will result in death or serious injury.
Disconnect the power supply and the connection cable before you
replace the device fuse.
1. Disconnect the power supply to the device.
2. Remove the connection cable.
3. Pry out the fuse insert (fig. 4 2, page 5) with a screwdriver.
4. Replace the defective glass fuse with a new one that has the same type and rat-
ing (4 A, 250 V).
5. Press the fuse insert back into the housing.
6. Reconnect the power supply to the device.
5.11
Replacing the device DC fuse
1. Disconnect the power supply to the device.
2. Pry out the fuse cover (fig. 4 3, page 5) to access the fuse.