Velleman DEM105 Manual Del Usuario página 10

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
9.8 Combination Lock
The DEM105 meter comes with a combination lock. To default security code
is 0000. To change the security code:
1.
Press the button with a small screwdriver.
2.
Set your security code by turning the code wheels.
3.
Release the button.
10. Cleaning and Maintenance
Wipe the device regularly with a moist, lint-free cloth. Do not use
alcohol or solvents. DO NOT submerge the device in any liquid.
Store the meter in a dry place away from humidity and vibrations.
Remove the battery when the meter is to be stored for long periods of
time.
11. Technical Specifications
relative humidity
overall range
accuracy
(0 % ~ 30 %
and 70 % ~ 100 %)
accuracy
(30 % ~ 70 %)
temperature
overall range
accuracy
(0° C ~ 70° C /
32° F ~ 158° F)
accuracy
(-40° C ~ 0° C /
-40° F ~ 32° F)
logging rate
power supply
V. 03 – 10/01/2022
DEM105
0 ~ 100 % RH
± 5.0 % RH
± 3.0 % RH
-40° C ~ 70° C (-40° F ~ 158° F)
± 1° C
± 1.5° C
selectable sampling interval: from 1 sec to
24 hours, operating temperature -35° C to 80° C
(-31° F to 176° F)
1 x lithium 3.6 V/1200 mAh SAFT ½ AA (incl.)
10
©Velleman Group nv
loading