We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
The objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light-output very quickly. The venting slots should be cleaned monthly.
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp and the fuse. Maintenance and service
operations are only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamps".
Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Dimensions:
Weight:
Maximum ambient temperature t
Maximum housing temperature t
Fuse:
Accessory:
PHILIPS CDM-R 70W/830 PAR30L10° spot E27
PHILIPS CDM-R 70W/830 PAR30L40° flood E27
Barn doors ML-64 Multi Spot black
Barn doors ML-64 Multi Spot silver
Please note: Every information is subject to change without prior notice. 22.11.2004 ©
CAUTION!
230 V, 50 Hz ~
80 W
170 x 170 x 300 mm
3.4 kg
45° C
:
a
(steady state):
90° C
B
F 1 A, 250 V
No. 91014610
No. 91014620
No. 41600180
No. 41600184
20/37
41600165_V_1_1.DOC
loading