Adeo Group OEM2 S026OEM2 Manual De Usuario E Instalacion página 54

Idiomas disponibles
  • ES

Idiomas disponibles

1. Loosen the screws and remove E-parts cover from
the unit.
2. Connect the cables respectively to the corresponding
terminals of the terminal board of the outdoor unit
(see the wiring diagram), and if there are signals
connected to the plug, just conduct butt joint.
3. Ground wire: Remove the grounding screw out
of the electric bracket, cover the grounding wire
end onto the grounding screw and screw it into
the grounding hole.
4. Fix the cable reliably with fasteners (Pressing board).
5. Put the E-parts cover back in its original place and
fasten it with screws.
Constant speed
Power
Connector
lf there is a connector, connect it directly.
Note: *This manual contains the connection form of different air conditioners. You
must choose the scheme that corresponds to that of the purchased device.
*This wiring diagram is for reference only. If the wiring diagram is different from that
of your appliance, the detailed wiring diagram fixed on the machine body prevails.
Installation for outdoor unit
Wiring connection
Wiring diagram
To indoor unit
23
Variable speed
To indoor unit
To indoor unit
E-parts
cover
Power
Power
loading