3.
Remove the side panels on both sides of the cassette housing.
4.
Loosen the screws holding the lamp, unfasten its connections and pull
out the lamp.
5.
Install the new lamp in the cassette in the reverse order of removal.
DISPOSAL OF USED UNITS.
At the end of its useful life, this product should not be disposed of with normal
household waste but should be taken to a collection point for the recycling of
electrical and electronic equipment. This is indicated by the symbol on the
product, operating instructions or packaging. The materials used in this unit are
recyclable according to their marking. You will be making an important
contribution to protecting our environment by reusing, recycling or otherwise
disposing of used units.
Your local administration will provide you with information about the
appropriate disposal point for used units.
TROUBLESHOOTING
Problem
Cassette/Lamp
does not work
Radiator
(cassette) does
not switch off
Display shows
nothing or
displays
incomplete
information
Time and
temperature
cannot be set
Possible cause
a) Damaged
b) Not connected
c)
Defective thyristor
module
a) Defective thyristor
module
a) Disconnected flat
wire on control
board
b) Defective display
a) Defective
potentiometers
b) Defective timer
Action
a) Check lamp
b) Check
cassette/lamp
connection
c)
Check thyristor
module
a) Check thyristor
module
a) Check flat cable
connection
b) Check the display
a) Check the operation
of the
potentiometers
b) Check the timer