INSTALLATION OF KIT MODEL
"UNICO AIR"
1 - DESCRIPTION OF THE COMPONENTS (Fig.1)
1.
Wired heating cable
F.
Female connections of the heating cable
M.
Male connections of the heating cable
2 - INSTALLATION OF THE HEATING CABLE
a.
Undo the screws (2a) of the rear panel (2) (fig.2).
b.
Remove the rear panel (2) (fig.2).
c.
Disconnect the two faston (3) of the cable (C) from the thermal-actuator (T) (fig.3).
d.
Position the heating cable (1) as shown in figure 4. Force its curvature between the veining (5) (fig.5).
e.
Complete the path of the heating cable (1) up to the mark (6), then make it come out from the basin
(B).
The mark (6) positioned on the heating cable (1) MUST remain inside the basin
(fig.6).
Pay attention NOT to position the heating cable (1) under the floats (4)
(Fig.7).
f.
Connect the female connections (F) of the heating cable (1) to the respective male faston (7) of the
thermal-actuator (T) (fig.8).
g.
Connect the male connections (M) of the heating cable (1) to the female faston (3) of the cable (C)
(fig.9).
h.
Once positioning of the heating cable (1) is complete and the respective connections are connected,
remount the rear panel and tighten the screws (2a).
EN - 2