FOR BATTERY TOOLS
The ambient temperature range for the use and storage of tool and battery is 0°C-45°C.
The recommended ambient temperature range for the charging system during charging is 0°C-40°C.
TROUBLESHOOTING TABLE
The following table gives checks and actions that you can perform if your machine does not operate
correctly. If these do not identify/remedy the problem, contact your service agent.
WARNING: Switch off and remove the battery pack before investigating fault.
Symptom
Pruning saw fails to
operate
Pruning saw
operates
intermittently
Chain/chain bar
over-heats
Pruning saw rips,
vibrates, does not
saw properly
18
EN
DECLARATION OF
CONFORMITY
We,
Positec Germany GmbH
Postfach 32 02 16, 50796 Cologne, Germany
On behalf of Positec declare that the product
Battery-powered pruning saw
Description
Type
KG343E KG343E.X (3-designation of
machinery, representative of battery-operated
pruning saw)
Function
Cutting wood
Complies with the following Directives:
2006/42/EC, 2014/30/EU,
2011/65/EU&(EU)2015/863,
2000/14/EC amended by 2005/88/EC
The notified body involved
Name: SGS Fimko Ltd
Address: Takomotie 8, FI-00380 Helsinki,
Finland
Certification No.: MD-347
2000/14/EC amended by 2005/88/EC:
- Conformity Assessment Procedure as per
Annex V
- Measured Sound Power Level
- Declared Guaranteed Sound Power Level
97 dB(A)
Possible Cause
Out of battery.
Fuse faulty.
Over heating
Applying too much pressure
while cutting.
Loose connection.
Internal wiring defective.
On/Off switch defective.
Chain is over tensioned
Dull chain
Chain tension too loose
Dull chain
Chain worn out
Chain teeth are facing in the
wrong direction
94 dB(A)
Remedy
Charge the battery pack.
Replace fuse.
Place the machine in a cool, ventilated
place to cool it down
Applying relatively less pressure while
cutting
Contact service agent.
Adjust chain tension
Sharpen chain or replace
Adjust chain tension
Sharpen chain or replace
Replace chain
Reassemble with chain in correct
direction
Standards conform to
EN 62841-1, EN 12100, EN ISO 3744, EN 55014-1,
EN 55014-2
The person authorized to compile the technical file,
Name
Marcel Filz
Address
Positec Germany GmbH
Postfach 32 02 16, 50796 Cologne, Germany
2022/07/19
Allen Ding
Deputy Chief Engineer, Testing & Certification
Positec Technology (China) Co., Ltd
18, Dongwang Road, Suzhou Industrial
Park, Jiangsu 215123, P. R. China