TOP VIEW
POWER SUPPLY
VIDEO LOAD
POWER SUPPLY
The ISO HUB has a pair of terminals to connect a power supply of +24 Vdc. This is the recommended operation mode.
If there is not connected any power supply to terminals, the ISO HUB draws power from the line input. It is
recommended to carry no more than two ISO HUB units, in this configuration.
Regardless of whether the ISO HUB is powered from the line input or from the power supply terminals, the power will
be present in the line output, for the rest of the installation.
The ISO HUB requires 100 mA maximum, in standby mode.
The power supply has two associated LEDs, a yellow one and a green one.
INDICATOR LIGTHS
They are placed in the connectors.
Line input:
- Green led off: the ISO HUB is remotely powered, which is provided through its line input.
- Green led on: The ISO HUB is locally powered from a power supply connected to its terminals. This is the
recommended option.
- Yellow led off: the ISO HUB is not powered, so it is not working.
- Yellow led on: the ISO HUB is powered and working.
Line output carry:
- Red leds off: video load is not connected. It must be this way when the line output carry is used.
- Red leds on: video load is connected. This is in case the line output carry is not used.
- Outputs to monitors:
- Green led off: the output does not supply power, because it has nothing connected or has detected a fault.
- Green led on: the output supplies power.
- Red led off: no fault has been detected.
- Red led on: an overcurrent on the output has been detected.
- Red led flickering: there has been a communication error on the output.
LINE OUTPUT CARRY
It is the RJ-45 connector called 'OUT'.
It sends the digital AUTA system signals to the rest of the installation.
This output will remain unused when the ISO HUB is the last of its riser. In that case the video load must be connected.
Then it will be indicated by the connector's red leds.
OUTPUTS TO MONITORS
The ISO HUB provides four outputs identified from 1 to 4.
They are able to connect a monitor to each one, up to 50 m far away from the ISO HUB.
VERY IMPORTANT
- The ISO HUB cannot be used to generate risers.
- Only ISO E-COMPACT monitors can be connected to the outputs to monitors.
OUT
IN
OUT
RESET
1
INPUT LINE CARRY
OUTPUT LINE
OUT
OUT
OUT
2
3
4
ISO HUB OUTPUTS
ISO HUB