Safety instructions
During the transport of loads, improper handling and/or poor maintenance of the lifting gear result in significant
hazards which can lead to serious accidents with sometimes fatal injuries. Please read and observe the information
and safety instructions contained in this operating manual very carefully and contact the manufacturer should you
have any questions.
Always...
activate the lifting magnet completely
activate the lifting magnet on metallic, ferromagnetic materials
use the whole magnetic surface for lifting
lift on level surfaces
check the magnetic holding force by lifting the load slightly by about 10 cm
clean the magnetic surface and keep it clear of dirt, chips, welding sputter
set the lifting magnet down gently to prevent damage to the magnetic surface
check the magnetic surface and the entire lifting magnet for damage
use suitable lifting gear
follow the instructions in the operating manual
familiarise new users with the safe use of lifting magnets and read and understand the
operating manual
observe local, country-specific guidelines
store in dry conditions
Never...
lift round or arched objects
lift more than the specified maximum load
transport loads above people's heads
lift several workpieces at once
switch the lifting magnet off until the load has been set down carefully
set the load swinging or stop it abruptly
lift loads which do not have the recommended sizes
lift loads with cavities, cut-out openings or drilled holes
lift uneven loads
turn loads from horizontal to vertical
turn the load hook under load
modify the lifting magnet or remove signs
use the lifting magnet when damaged or when parts are missing
strain the underside of the magnet through heavy impact or blows
stand under the lifted load
lift loads when there is someone in the hazard area
leave the load unattended
use the lifting magnet without having been properly instructed
use the lifting magnet to support, lift or transport persons
operate the lifting magnet at temperatures above 60°C (140°F)
bring into contact with corrosive substances
People with cardiac pacemakers or other medical appliances may only use the lifting magnet
following approval by their physician.