Do not damage any part of the refrigerant circuit.
•
Be aware R600a refrigerant is odourless and does not
have the odour normally associated with natural gas and
propane tanks.
•
Do not use means to accelerate the defrosting process
or to clean, other than those recommended by the
manufacturer.
•
The appliance must be placed in an area without any
continuous sources of ignition such as open flames, gas,
or electrical appliances in operation.
•
Do not puncture and do not burn.
•
If the appliance is installed, operated or stored in a non-
ventilated area, the room must be designed to prevent
the accumulation of refrigerant leaks resulting in a risk of
fire or explosion due to ignition of the refrigerant caused
by electric heaters, stoves, or other sources of ignition.
•
Do not store explosive substances such as aerosol cans
with a flammable propellant in this appliance.
•
The appliance must be stored in such a way as to
prevent mechanical failure.
•
Individuals who operate or work on the refrigerant circuit
must have the appropriate certification issued by an
accredited organisation that ensures competence in
handling refrigerants according to a specific evaluation
recognised by associations in the industry.
•
Maintenance and repairs that require the assistance
of other qualified personnel must be performed under
the supervision of an individual specified in the use of
flammable refrigerants.