Dexter power JL811201 Instrucciones Legales Y De Seguridad página 78

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
• Activate the air tool shortly, so the pressure gauge (7) will show the right pressure level
• Turn the pressure regulator turning knob (5) clockwise, till the pressure gauge (7) shows the
pressure level you need
• Your air tool is now ready to use.
Note: when not connecting an air tool while adjusting the pressure, it
might occur the pressure gauge (7) is not reacting accurately on the
pressure drop
Make sure that the plug is removed from the mains when carrying
out maintenance
The machine has been designed to operate over a long period of time with a minimum of
maintenance. Continuous satisfactory operation depends upon proper machine care and
regular cleaning. Before interfering in any way whatsoever with the compressor, please make
sure that:
• The switch button is in the "0" position and the power plug is removed from the power socket
• The air tank is fully decompressed (both pressure gauges must be pointed at 0 Bar)
• The air in the tank can be eliminated by the air tool.
Cleaning
Regularly clean the machine housing with a soft cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water. Never use solvents
such as petrol, alcohol, ammonia water, etc.These solvents may damage the plastic parts.
Drain the tank
Compressing air will cause water in the tank.
Regularly drain the water from the tank to prevent tank corrosion :
• First reduce the pressure in the tank till approximately 2 bar by connecting and activating an
air tool .
• Then slowly turn the drain valve (14) on the lower side of the tank open.
11
6. OPERATION
7. MAINTENANCE
EN
loading

Productos relacionados para Dexter power JL811201