Sammic AT-3 Manual De Instrucciones página 77

Ocultar thumbs Ver también para AT-3:
Idiomas disponibles

Idiomas disponibles

PAR.
DEFAULT
MIN.
C0
0
0
C1
5
0
C2
3
0
C3
0
0
C4
10
0
C5
10
0
C6
80
0
C7
90
0
C8
1
0
C9
30
0
PAR.
DEFAULT
MIN.
d0
8
0
d1
1
0
d2
2
-50
MAX.
U.M.
COMPRESSOR PROTECTION
Minimum time between restoration of power supply after a
240
min
power
failure
compressor switch-on
240
min
Minimum time between two consecutive compressor switch-ons
Minimum time between compressor switch-off and subsequent
240
min
switch-on
240
s
Minimum compressor-on time
Compressor-off time during cabinet probe error ("CABINET
PROBE" code) occurring during conservation after blast chilling
240
min
and blast freezing;
see also parameters C5 and C9
Compressor-on time during cabinet probe error ("CABINET
PROBE"
240
min
chilling;
see also parameter C4
Condenser temperature above which the condenser overheating
199
ºC
alarm is activated ("COND OVERHEATING" code)
Condenser temperature above which the compressor locked
199
ºC
alarm is activated ("COMP LOCKED" code), once the time set
for C8 has elapsed
Activation delay of the compressor locked alarm ("COMP
15
min
LOCKED" code) due to threshold C7 exceeded
Compressor-on time during cabinet probe error ("CABINET
PROBE"
240
min
freezing;
see also parameter C4
MAX.
U.M.
DEFROST
Defrost interval
99
h
0 = defrosting during conservation is never activated
Type of defrost
0 =
electrical (during defrosting the compressor is switched
off, the defrost output is activated and the evaporator
fan switched off)
1 = hot gas (during defrosting the compressor is switched
on, the defrost output is activated and the evaporator
fan is switched off)
3
- - - -
2 = air (during defrosting the compressor is switched off and
the defrost output is activated. The evaporator fan is
switched on, regardless of the door status, or regardless
of the status of the door switch input)
3 = air with door open (during defrosting the compressor is
switched off and the defrost output is activated. The
evaporator fan is switched on, provided the door is open
or provided the door switch input is on and that
parameter i0 is set to a value other than 0)
Evaporator temperature to end defrosting;
99
ºC
see also parameter d3
24
occurring
during
an
code)
occurring
during
conservation
code)
occurring
during
conservation
operating
cycle
and
after
blast
after
blast
EN
loading

Este manual también es adecuado para:

At-5At-8At-10At-12At-14At-20