The new superheterodyne receiver always guarantees a correct
functioning in disturbed environments: its good sensitivity and high
selectivity make it immune from most disturbances around the
frequency reception area.
• It is possible to store 240 different codes with self-learning mode.
• Memory full warning: the receiver blinks 15 times.
PROGRAMMING OF THE MONOSTABLE FUNCTION
The monostable function activates the corresponding relay through the
time of tx transmission. When the transmission stops, the relay goes
automatically off.
1 Press P1 push-button of the receiver: L1 led switches on.
2 Release the push-button, the led switches off and it sends out a
sequence of single flashings for 5 seconds: the number of short
flashings shows the selected channel.
3 To select the further channels press and release the P1 push-button
within 5 seconds, the led changes type of flashing according to the
following table:
SELECTED
N°IMPULSES
Single
CHANNEL
P1
flashing
CHANNEL 1
1
CHANNEL 2
2
CHANNEL 3
3
CHANNEL 4
4
4 Choose the channel you want to memorize and within 5 seconds
press and hold the push-button of the transmitter.
5 The LED of the receiver is on for 3 seconds to confirm the storage.
6 The LED blinks again waiting for a new transmitter to store; it is
possible to store in sequence up to 240 different codes
ADVANCED PROGRAMMING
BISTABLE FUNCTION: it activates the corresponding relay on the first
tx transmission. The relay goes off on the second transmission.
Repeat the procedure described in the paragraph" Programming of the
Monostable Function" up to point 4, therefore proceed as it follows:
5 The LED of the receiver is on for 3 seconds: press the
pushbutton P1 of the receiver within 3 sec.
6 Led L1 starts a sequence of flashings at low speed (1 flash per
second).
7 After the thirtieth flash the led L1 remains on for 5 seconds.
8 Press and release the pushbutton P1 within 5 seconds.
9 The LED of the receiver is on for 3 seconds to confirm the storage.
10 The LED blinks again waiting for a new transmitter to store; it is
possible to store in sequence up to 240 different codes.
TIMER FUNCTION: the tx transmission activates the corresponding
relay which goes off after the set time (max 7,5 minutes).
Repeat the procedure described in the paragraph" Programming of the
Monostable Function" up to point 4, therefore proceed as it follows:
5 The LED of the receiver is on for 3 seconds: press the
pushbutton P1 of the receiver within 5 sec.
6 Led L1 starts a sequence of flashings at low speed (1 flash per
second).The number of flashing corresponds to the time which can
be set as shown in the table.
Double
Triple
Quadruple
flashing
flashing
flashing
••
•••
••••
7 Count the number of led L1 flashings corresponding to the time you
wish to set. Press the RX button P1 during the wished flashing.
8 The blinking quit and the LED1 is on for 3 seconds to confirm the
storage.
9 The LED blinks again waiting for a new transmitter to store; it is
possible to store in sequence up to 240 different codes.
TIME
FLASHING
FLASHING
1
01 sec.
12
2
02 sec.
13
3
03 sec.
14
4
04 sec.
15
5
05 sec.
16
6
06 sec.
17
7
07 sec.
18
8
08 sec.
19
9
09 sec.
20
10
10 sec.
21
11
11 sec.
22
REMOTE RADIO LEARNING
This procedure allows to memorize new transmitters by radio, in
sequence and without removing the receiver from the installation.
The transmitter which allows to enable the programming by radio must
be memorized in advance. All transmitters programmed by radio will
share the same key configuration as the transmitter which activated
the programming.
Example: TX A transmitter memorized with the following key
configuration:
Key 1 on the first channel in monostable mode.
Key 2 on the third channel in timer mode.
Key 3 on the fourth channel in bistable mode.
TX B transmitter to memorize.
• Hold for 5 seconds minimum the keys 1+2 or 1+3 of TX A: L1 led
switches on.
• Release both keys.
• Press, within 5 seconds, the required key of TX B.
• Release and press within 5 seconds on the TX B another key to be
memorized. Repeat this operation for other transmitters.
• To exit the self-learning mode wait for at least 5 seconds.
The key configuration of TX B transmitter and other transmitters, set
with this procedure, will be the same as TX A transmitter.
FULL CODE ERASING
To perform a full code erasing do the following:
• Switch off the power supply of the control unit where the
receiver is connected.
• Press and hold pressed the P1 key of the receiver
• At the same time turn on the power again. The receiver LED goes
on: release the P1 key.
The memory spaces are empty and available for a new programming.
99/05/CE DIRECTIVE CONFORMITY
The 900RXI-44 / 900RXI-44R is in conformity with the provisions of the
following EC directive(s) (including all applicable amendments) and that
the standards referenced here below:
EN 60335-1, EN 301 489-3, EN 300 220-3
Pianzano di Godega S.Urbano, 04/10/2002
KEY AUTOMATION S.R.L. legal representative
R. Bissoli
TIME
TIME
FLASHING
12 sec.
23
4 min.
13 sec.
24
4,5 min.
14 sec.
25
5 min.
15 sec.
26
5,5 min.
30 sec.
27
6 min.
1 min.
28
6,5 min.
1,5 min.
29
7 min.
2 min.
30
7,5 min.
2,5 min.
31
BISTABLE
3 min.
3,5 min.
(900RX-44R only)
loading

Este manual también es adecuado para:

900rxi-44r